Article Detail

Home > Article Detail
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility

Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
2010, v.23 no.1, pp.24-35
https://doi.org/10.5806/AST.2010.23.1.024


  • Downloaded
  • Viewed

Abstract

To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs (H2S, CH3SH, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000ppb) along with CS2 as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.

keywords
Reduced sulfur compounds, external calibration, internal calibration, internal standard, FSC, FSV


Reference

1

1. A. T. Nielsen and S. Jonsson, J. Chromatography A, 963, 57-64(2002).

2

2. 전선주, 허귀석, 한국대기환경학회지, 15(4), 417- 428(1999).

3

3. K. H. Kim, H. Swan, Z. H. Shon, G. Lee, J. Kim and C. H. Kang, Chemosphere, 54(4), 515-526(2004).

4

4. W. C. Kuster and P. D. Goldan, Environ. Sci. Technol., 21(8), 810-815(1987).

5

5. 최여진, “대기 중 VOC와 악취성 환원황화합물의 관측기술에 대한 연구,” 세종대학교 석사학위논문, (2004).

6

6. K. H. Kim, J. Separation Sci., 31(10), 1761-1768(2008).

7

7. 이기한, 김기현, 한국냄새환경학회지, 6(3), 183- 193(2007).

8

8. 김기현, 오상인, 최여진, 최규훈, 주도원, 한국대기환경학회지, 19(6), 679-687(2003).

9

9. S. K. Pandey and K. H. Kim, Analytica Chimica Acta, 615(2), 165-173(2008).

10

10. M. Eriksson, J. Fäldt, G. Dalhammar and A. K. B. Karlson, Chemosphere, 44(7), 1641-1648(2001).

11

11. R. J. C. Brown, M. R. Roberts and D. J. L. Brett, Analytica Chimica Acta, 635, 1-5(2009).

12

12. R. J. Bartelt and B. W. Zilkowski, Anal. Chem., 72, 3949-3955(2000).

13

13. J. Malicki, A. Montusiewicz and A. Bieganowsk, Wat. Res., 35(9), 2333-2335(2001).

14

14. H. Sela, Z. Karpas, M. Zoriy, C. Pickhardt and J. S. Becker, International Journal of Mass Spectrometry, 261, 199-207(2007).

15

15. J. R. Fernndsz, R. Pereiro and A. S. Medel, Analytica Chimica Acta, 471, 13-23(2002).

16

16. 홍원필, 김기현, 한국냄새환경학회지, 7(4), 238- 245(2008).

17

17. 김기현, 한국냄새환경학회지, 7(3), 170-178(2008).