바로가기메뉴

본문 바로가기 주메뉴 바로가기

(사)한국터널지하공간학회

Evaluation of tensile properties of SFRC for TBM tunnel segment

(사)한국터널지하공간학회 / (사)한국터널지하공간학회, (P)2233-8292; (E)2287-4747
2012, v.14 no.3, pp.247-260




  • Downloaded
  • Viewed

Abstract

In order to reduce the amount of steel reinforcements in TBM tunnel segments, the use of Steel Fiber Reinforced Concrete(SFRC) is being tried. The steel fibers with higher aspect ratio than that used in tunnel shotcrete are preferred to compensate the deficiency in tensile strength of the segments. In this study, the tensile properties of SFRC with aspect ratio of steel fibers equal to 80 were evaluated through flexural test and Double Punch Test. In the results of flexural test, flexural strengths of the SFRC were increased about 30%~150% thanks to bond of steel fibers used to concrete and could be properly predicted by the equation proposed by Oh(2008). There was a great difference in the estimated direct tensile strengths of the SFRC by the equations presented in ACI and RILEM. It was found that the Double Punch Test could be suitable methodology to estimate the direct tensile strength presented in RILEM of the SFRC.

keywords
Double punch test, 인장강도, 강섬유 보강 콘크리트, Double punch test, tensile strength, SFRC

Reference

1.

김상명, 신진용, 마상준, 남관우, 김기호 (2008), “숏크리트 구성재료에 따른 콘크리트 성능에 관한 실험적연구”, Vol. 10, No. 1, pp. 59-68.

2.

문도영, 이규필, 장수호, 배규진 (2011), “강섬유보강 콘크리트 세그먼트의 강섬유가 표면전기저항에 미치는 영향”, Vol. 13, No. 6, pp. 557-569.

3.

송용수, 류종현, 임희대 (2010), “숏크리트의 조기강도에 대한 실험적 연구”, Vol. 12, No. 4, pp. 285-294.

4.

오영훈 (2008), “갈고리형 강섬유를 혼입한 보통 힘 및 고강도 콘크리트의 휨강도 평가”, 콘크리트학회논문집, Vol. 20, No. 4, pp. 531-539.

5.

KS F 2405 (2005), “콘크리트의 압축강도 시험방법”, 한국표준협회.

6.

KS F 2566 (2010), “강섬유 보강 콘크리트의 휨인성 시험방법”, 한국표준협회.

7.

ASTM C 1609M (2007), “Standard test method for flexural performance of Fiber-Reinforced Concrete (Using beam with Third-Point loading)”, ASTM.

8.

Chiaia, B, Fantilli, A. P., Vallini, P. (2009), “Combining fiber-reinforced concrete with traditional reinforcement in tunnel linings”, Engineering Structures, Vol. 31, pp. 1600-1606.

9.

Cho, S.H., Karki, N.B., Cho, J.S., Waweru, R.N. (2012), “Use of Double Punch Test to Evaluate the Mechanical Performance of Fiber Reinforced Concrete”, HPFRCC 6, pp. 27-34.

10.

Dobashi, H., Konishi, Y., Nakayama, M., Matsubara, K. (2006), “Development of steel fiber reinforced high fluidity concrete segment and application to construction”, Tunneling and Underground Space Technology, Vol. 21, p. 422.

11.

Malatesta, S.C., Aguado, A., Molins, C., Cabrera, M. (2009), “Quality control of fiber reinforced concretes by mean of double punshing test (barcelona test)”, Revista Ingenieria de Construccion, Vol. 24, No. 2, pp. 119-140.

12.

Malatesta. S.C., Aguado, A., Molins, C. (2012), “Generalization of the Barcelona test for the toughness control of FRC”, Materials and Structures, RILEM 2011.

13.

Mangat, P.S., Gurusamy, K. (1987), “Long-term properties of steel fibre reinforced marine concrete”, Materials and Structures, Vol. 20, pp. 273-282.

14.

Molins, C., Aguado A., Saludes, S. (2008), “Double Punch Test to control the energy dissipation in tension of FRC (Barcelona test)”, Materials and Structures, Vol. 42, No. 4, p. 415.

15.

RILEM TC 162-TDF (2003), “design method-final recommendation”, Materials and Structures, Vol. 36, pp. 560-567.

16.

Song, P.S., Hwang, S. (2004), “Mechanical Properties of High-Strength Steel Fiber-Reinforced Concrete”, Construction and Building Materials, Vol. 18, pp. 669-673.

17.

Wafa, F.F., Ashour, S.A. (1992), “Mechanical Properties of High-Strength Fiber Reinforced Concrete”, ACI materials Journal, Vol. 89, No. 5, pp. 449-455.