바로가기메뉴

본문 바로가기 주메뉴 바로가기

ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

logo

A Study on the Odor Removal Control System of Sewage Sludge

웰빙융합연구 / Journal of Wellbeing Management and Applied Psychology, (E)2586-6036
2021, v.4 no.2, pp.19-25
https://doi.org/https://doi.org/10.13106/jwmap.2021.vol4.no2.19
KIM, Su-Hye (Department of Environmental health and Safety, Eulji University)
LEE, So-Hee (Department of Environmental health and Safety, Eulji University)
YUN, Yeo-Jin (Department of Environmental health and Safety, Eulji University)
CHOI, Soo-Young (Department of Environmental health and Safety, Eulji University)
JUNG, Min-Jae (Department of Environmental health and Safety, Eulji University)
KWON, Woo-Taeg (Department of Environmental health and Safety, Eulji University)

Abstract

Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

keywords
Sewage treatment facility, Water regeneration center, Odor removal, Odor complaint, Reduction measurement

웰빙융합연구