OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가

Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence

식품보건융합연구 / The Korean Journal of Food & Health Convergence (KJFHC), (E)2586-7342
2018, v.4 no.1, pp.15-22
https://doi.org/https://doi.org/10.13106/kjfhc.2018.vol4.no1.15
Lee, Ju-seong (Department of Radiological Science, Eulji University)
Kang, Bo-ram (Department of Radiological Science, Eulji University)
Kwon, Hyeon-Kyung (Department of Radiological Science, Eulji University)
Park, Ji-Young (Department of Radiological Science, Eulji University)
Kim, Ju-Hye (Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong)
Choi, Young-Se (Department of Radiation Oncology, Yonsei Cancer Center)
Kim, Daehong (Department of Radiological Science, Eulji University)

Abstract

A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are <TEX>$0^{\circ}{\pm}80^{\circ}$</TEX> with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from <TEX>$0^{\circ}$</TEX> to <TEX>${\pm}80^{\circ}$</TEX> for both OSLD and EBT3 film. When angle of <TEX>$0^{\circ}$</TEX> is normalized to 1, and the dose is decreased to 60 and 66% at <TEX>$80^{\circ}$</TEX> for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from <TEX>$0^{\circ}$</TEX> to <TEX>${\pm}80^{\circ}$</TEX> for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.

keywords
OSLD, EBT3 film, Dose dependence, Energy dependence, Angular dependence