바로가기메뉴

본문 바로가기 주메뉴 바로가기

Computer-Aided Diagnosis in Chest CT

Tuberculosis & Respiratory Diseases / Tuberculosis & Respiratory Diseases,
2004, v.57 no.6, pp.515-521

  • Downloaded
  • Viewed

Abstract

With the increasing resolution of modern CT scanners, analysis of the larger numbers of images acquired in a lung screening exam or diagnostic study is necessary, which also needs high accuracy and reproducibility. Recent developments in the computerized analysis of medical images are expected to aid radiologists and other healthcare professional in various diagnostic tasks of medical image interpretation. This article is to provide a brief overview of some of computer-aided diagnosis schemes in chest CT. (Tuberc Respir Dis 2004; 57:515-521)

keywords
Computer-aided diagnosis, Computed tomography, Lung nodule, Screening, Computer-aided diagnosis, Computed tomography, Lung nodule, Screening

Reference

1.

(2001) Computer-aided diagnosis in chest radiography:a survey,

2.

(2000) Data explosion:the challenge of multi- detector-row CT,

3.

(2003) Multi-detector row CT of the central airway disease,

4.

(1999) Early Lung Cancer Action Project:overall design and findings from baseline screening,

5.

(2002) Screening for lung cancer with low-dose spiral computed tomography,

6.

(2003) Screening for lung cancer with low-dose computed tomography,

7.

(1999) Detection failures in spiral CT screening for lung cancer:analysis of CT findings,

8.

(2002) Lung cancers missed at low-dose helical CT screening in a general population:comparison of clinical,histopathologic,and imaging findings,

9.

(1994) Computerized detection of pulmonary nodules in computed tomography images,

10.

(1998) Computer-aided diagnosis for pulmonary nodules based on helical CT images,

11.

(2001) Chest CT:automated nodule detection and assessment of change over time--preliminary experience,

12.

(2002) Automatic detection of pulmonary nodules at spiral CT:clinical application of a computer- aided diagnosis system,

13.

(2002) Lung cancer:performance of automated lung nodule detection applied to cancers missed in a CT screening program,

14.

(2003) Automated lung nodule detection at low-dose CT:preliminary experience,

15.

(2003) Lung micronodules:automated method for detection at thin-section CT--initial experience,

16.

(2004) Pulmonary nodules at chest CT:effect of computer-aided diagnosis on radiologists' detection performance,

17.

(2004) The potential contribution of a computer-aided detection system for lung nodule detection in multi- derector row computed tomography,

18.

(2002) CT screening for lung cancer frequency and significance of part-solid and nonsolid nodules,

19.

(1996) Bronchioloalveolar carcinoma:focal area of ground-glass attenuation at thin-section CT as an early sign,

20.

(2000) Evolution of peripheral lung adenocarcinomas:CT findings correlated with histology and tumor doubling time,

21.

(2004) Progression of focal pure ground-glass opacity detected by low-dose helical computed tomography screening for lung cancer,

22.

Computer-aided detection of localized ground-glass opacity in the lung on CT images,

23.

(1996) Glossary of terms for CT of the lungs:recommendations of the Nomenclature Committee of the Fleischner Society,

24.

(2000) Spiral CT of pulmonary nodules:inter- observer variation in assessment of lesion size,

25.

(2004) On the testing and reporting of computer-aided detection results for lung cancer detection,

26.

(2003) Posterior subpleural nodules in patients with underlying malignancies:value of the prone computed tomo- graphy,

27.

(2003) Interobserver and intraobserver variability in measurement of non- small-cell carcinoma lung lesions:implications for assessment of tumor response,

28.

(2000) Small pulmonary nodules:volumetrically determined growth rates based on CT evaluation,

29.

(2004) Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography,

30.

(2003) Small pulmonary nodules:volume measurement at chest CT--phantom study,

31.

Volumetric measurement of synthetic lung nodules with multi-detector row CT effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy Radiology in press,

32.

(2004) Volumetric measurements of pulmonary nodules at multi-row detector CT:in vivo reproducibility,

33.

(2004) Small pulmonary nodules:reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT,

34.

(1999) A pattern classification approach to characterizing solitary pulmonary nodules imaged on high resolution CT:preliminary results,

35.

(2003) Fractal analysis of internal and peripheral textures of small peripheral bronchogenic carcinomas in thin-section computed tomography:comparison of bronchioloalveolar cell carcinomas with nonbronchi- oloalveolar cell carcinomas,

36.

(2003) Ex- ample-based assisting approach for pulmonary nodule classification in three-dimensional thoracic computed tomography images,

37.

(2004) CT perfusion image of the lung:value in the detection of pulmonary embolism in a porcine model,

38.

(2003) Landmark detection in the chest and registration of lung surfaces with an application to nodule registration,

39.

(2004) Lung image database consortium:developing a resource for the medical imaging research community,

Tuberculosis & Respiratory Diseases