The purpose of this study was to give a guideline for selecting the nickel-titanium (NiTi) file by review from many studies. Since the early 1990s, several instrument systems manufactured from NiTi have been introduced into endodontic practice. The specific design characteristics vary, such as tip shape and size, cross sectional view, helix angle, and pitch space. Some of the early systems have been removed from the market or play only minor roles; others are still widely used. New designs continually are produced, but the extent to which clinical outcomes will depend on design characteristics is difficult to forecast. In this study, I have reviewed the different design characteristics in respect of the safety and efficiency. With the review from many studies, I concluded that the clinicians must be understand the specific design characteristics for selecting the ideal NiTi rotary instruments.
1. Peters OA, Barbakow F, Peters CI, 'An analysis of endodontic treatment with three nickel-titanium rotary root canal preparation techniques', Int Endod J 37(2004), 849-859.
2. Hsu YY, Kim S, 'The ProFile system', Dent Clin North Am 48(2004), 69-85.
3. Roig-Cayon M, Basilio-Monne J, Abos-Herrandiz R, Brau-Aguade E, Canalda-Sahli C, 'A comparison of molar root canal preparations using six instruments and instrumentation techniques', J Endod 23(1997),383-386.
4. Kuhn WG, Carnes DL Jr, Clement DJ, Walker WA 3rd, 'Effect of tip design of nickel-titanium and stainless steel files on root canal preparation', J Endod 23(1997), 735-738.
5. Esposito PT, Cunningham CJ, 'A comparison of canal preparation with nickel-titanium and stainless steel instruments', J Endod 21(1995), 173-176.
6. Miserendino LJ, Moser JB, Heuer MA, Osetek EM, ‘Cutting efficiency of endodontic instruments. II. Analysis of tip design’, J Endod 12(1986). 8-12.
7. Serota KS, Glassman GD, ‘Root canal preparation using engine-driven nickel-titanium rotary instruments’, Pract Periodontics Aesthet Dent 11(1999), 1117-1118, 1120, 1122.
8. Baek SH, Lee Cj, Versluis A, Kim BM, Lee W, Kim HC, 'Comparison of torsional stiffness of nickeltitanium rotary files with different geometric characteristics', J Endod 37(2011), 1283-1286.
9. Blum JY, Machtou P, Micallef JP, ‘Location of contact areas on rotary Profile instruments in relation to the forces developed during mechanical preparation on extracted teeth’, Int Endod J 32(1999), 108-114.
10. McGreevey, E, ‘Investigation of profile series 29 .04 taper rotary instruments’, Boston, master's thesis, Boston University, 1995.