open access
메뉴ISSN : 0376-4672
Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.
1. Chung SY, Cho JH, Lee KB, Choi YH, Song KB. Structural equation modeling for association between patient satisfaction and quality of life after implant surgery. J Korean Acad Prosthodontics 2011; 49:291-9.
2. Shin HS, Bae KH, Lee BJ. The policy intervention for dental implant and bone graft material industry in Korea. Korea institute for health and social affairs 2009; 3-23.
3. Albrektsson T, Branemark PI, Hansson HA, Lindstro J. Osseointegrated titanium implants. :Requirements for ensuring a long lasting, direct bone ankorage in man. Acta Orthop Scand Vol. 1981; 52:155-170.
4. Eriksson RA, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital microscopic description of heat effects. Int J Oral Surg 1982; 1:115-121.
5. Eriksson RA, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit. J Prosthet Dent 1983; 50:101-107.
6. Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: An experimental study in rabbit using the bone growth chamber. J Oral Maxillofac Surg 1984; 42:705-711.
7. Yun JH, Jeon GR, Kim YJ, Jeong CM. Effect of simplified procedure of newly designed implant drill on the temperature changes and cutting time. J Korean Res Soc Dent Mater 2012; 39(1):9-16.
8. Kim DR, Kim MJ, Kwon HB, Lee SH, Lim YJ. In vitro study on the initial stability oftwo tapered dental implant systmes in poor bone quality. J Dent Rehabil Appl Sci 2009; 25(4):389-399.
9. Hwang ST, Han IH, Huh JB, Kang JK, Ryu JJ. Review of the developmental treandof implant surface modification using orfanic biomaterials. J Korean Acad Prosthodontics 2011; 49(3):254-262.
10. Lee SH, Kim YS, Kim WK, Lee YK. Immediate implant placement in areas on aesthetic priority. J Periodontal Implant Sci 2007; 37(3):637-646.
11. Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clinical Oral Implants Research 2009; 20:294-298.
12. Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986; 44:4?7.
13. Cordioli G, Majzoub Z. Heat generation during implant site preparation: An in vitro study. Int J Oral Maxillofac Implants 1997; 12:186-193.
14. Hyun Jun Oh, Ulf ME Wikesjö, Ho-Seong Kang, Young Ku, Tae-Gwan Eom, Ki-Tae Koo. Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Clinical Oral Implants Research 2011; 22:722-726.
15. Sharawy M, Misch CE, Weller N, Tehemar S. Heat Generation During Implant Drilling: The Significance of Motor Speed. J Oral Maxillofac Surg. 2002; 60(10):1160-9.
16. Brisman DL. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants. 1996; 11 (1):35-7.
17. Fanuscu MI, Chang TL, Akca K, Effect if surgical techniques on primary implant stability and periimplant bone. J Oral Maxillofac Surg 2007; 65:2487-2491.