바로가기메뉴

본문 바로가기 주메뉴 바로가기

ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

logo

메뉴

권호 목록

맞춤형 마우스가드의 효능과 실제
이성복(경희대학교) pp.602-609 https://doi.org/10.22974/jkda.2015.53.9.001
초록보기
초록

Abstract

The aim of this document is to evaluate the effect of bite balance on physical fitness and motor capacity to determine the importance of the occlusal stability as a possible action mechanism of occlusal appliance including mouthguards on physical performances. We all remember that day when the prominent athlete was in the news wearing a mouthguard to improve human athletic performance. I once had investigated the determinants of athletic performance in all sorts of sports. Most of the studies had overinterpretation of results and lack of evidence to support the information. However, I discovered great expectations for new possibility in this field and settled for a more academic approach to this intriguing subject. The followings are some examples of the subject 1. Archers who wore occlusal appliances to increase the vertical dimension of occlusion by 2~3mm increased their ability to focus and to maintain good sense of balance. Their accuracy rate has been improved. The appliance was made of acrylic resin (a type of plastic). 2. Canoe players who wore occlusal appliances to increase the vertical dimension of occlusion by 5mm surpassed longtime competitor and won the race with 10 seconds gap. 3. A cycle rider who wore an occlusal appliance to treat his malocclusion surpassed his old record from 10.8 seconds to 10.3 seconds. His muscle reflexes (anaerobic exercise) and endurance (aerobic exercise) has been enhanced. 4. Occlusal appliances had a good effect on athletic performance in most sports such as swimming, diving, and weightlifting. As for the clenching on dentition, people clench their teeth when they push their physical and mental limits during sports activities. Clenching can be induced by physical exertion when maximum muscle strength is retained and this is similarly found in different types of exercises. In addition, restraint of respiratory function is observed. Therefore, creating a occlusal balance with occlusal appliance or mouthguard promoted a favorable influence when an athlete clenches.

외상후 치아를 보전하는 방법
김수관(조선대학교) pp.610-613 https://doi.org/10.22974/jkda.2015.53.9.002
초록보기
초록

Abstract

Maxillofacial trauma with dental trauma tends to be increasing as development of civilization. Proper dental first aid is easy method to prevent further posiible complication. So we will describe on a simple dental treatment for traumatic teeth in this paper.

치과의사의 스포츠계에 책임과 기여
전명섭(강남로덴예쁜얼굴치과의원) pp.614-617 https://doi.org/10.22974/jkda.2015.53.9.003
Clinical effect of calcium chelating and deproteinizing agent containing dental conditioning gel on alleviation of periimplant mucosa inflammation
양광헌(단국대학교) ; 이주연(Central Research Institute) ; 정진형(단국대학교) ; 신현승(단국대학교) ; 조인우(단국대학교) pp.618-627 https://doi.org/10.22974/jkda.2015.53.9.004
초록보기
초록

Abstract

Purpose : The purpose of this clinical study was to evaluate the effect of chelating and deproteinizing agent containing dental conditioning gel on alleviation of peri-implant mucosa inflammation. Methods: 36 patients with functionally loaded implants for at least 1 year and have clinical signs of peri-implant mucositis were recruited. At baseline, all implants received subgingival prophylaxis with ultrasonic scaler. In the test group, patients were provided a chelating and deproteinizing agent dental conditioning gel (ClinplantⓇ) and were given instructions to applicate it around the implants using an interdental brush for 2 weeks. Chlorhexidine and saline were provided to the positive control group and negative control group, respectively. The modified sulcus bleeding index (mSBI), modified plaque index (mPI), and probing pocket depth (PPD) were evaluated at baseline, 1 week, and 2 weeks. Results: In the ClinplantⓇ and chlorhexidine group, mSBI (-0.81, -0.85 respectively; p<0.01), mPI (-0.46, -0.5 respectively; p<0.01), and PPD (-0.58, -0.48 respectively; p<0.01) at 2 weeks were significantly reduced from baseline. In the saline group, all the clinical parameters were reduced but there was no statistical significance. The saline may be attributed to the influence of prophylaxis at baseline. Conclusions: The present study demonstrated the beneficial clinical effects of chelating and deproteinizing agent containing dental conditioning gel to decrease peri-implant mucosa inflammation equivalent to chlorhexidine. This dental conditioning gel might be useful for alleviation of peri-implant mucosa inflammation.

위축된 상악구치부에서 두 개의 짧은 임플란트지지형 단일치관의 임상연구
송호용(춘천예치과의원) ; 허윤혁(강릉원주대학교) ; 박찬진(강릉원주대학교) ; 조리라(강릉원주대학교) pp.628-643 https://doi.org/10.22974/jkda.2015.53.9.005
초록보기
초록

Abstract

Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient’s age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student’s t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient’s age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was 45 ± 14.7 months. The mean marginal bone loss of survived 169 implants was 0.08 ± 0.59 mm. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향
윤보혁(부산대학교) ; 신현모(부산대학교) ; 윤미정(부산대학교) ; 허중보(부산대학교) ; 정창모(부산대학교) ; 강은숙(인제대학교) pp.644-655 https://doi.org/10.22974/jkda.2015.53.9.006
초록보기
초록

Abstract

Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

logo