Humidifier Disinfectant-Associated Lung Injury: Six Years after the Tragic Event

Tuberculosis & Respiratory Diseases / Tuberculosis & Respiratory Diseases,
2017, v.80 no.4, pp.351-357


  • Downloaded
  • Viewed

Abstract

In 2011, a cluster of peripartum patients were admitted to the intensive care unit of a tertiary hospital in Seoul with signs and symptoms of severe respiratory distress of unknown etiology. Subsequent epidemiological and animal studies suggested that humidifier disinfectant (HD) might represent the source of this pathology. Epidemiological studies, animal studies, and dose-response analysis demonstrated a strong association between HD use and lung injuries. The diagnostic criteria for HD-associated lung injury (HDALI) was defined on the basis of the clinical, pathological, and radiological attributes of the patients. The clinical spectrum of HDALI appears to range from asymptomatic to full-blown acute respiratory failure, and some patients have required actual lung transplantation for survival. The overall mortality of the exposed population was not significant, although peripartum patients and children who were admitted to the intensive care unit did show high mortality rates. Persistent clinical findings such as diffuse ill-defined centrilobular nodules and restrictive lung dysfunction were observed in some of the survivors. The findings of this review emphasize the importance of assessment of the level of toxicity of chemical inhalants utilized in a home setting, as well as the need to identify and monitor afflicted individuals after inhalational injury.

keywords
Humidifiers, Disinfectants, Lung Injury, Diagnosis, Prognosis, Review

Reference

1.

1. Jeon BH, Park YJ. Frequency of humidifier and humidifier disinfectant usage in Gyeonggi provine. Environ Health Toxicol 2012;27:e2012002.

2.

2. Hong SB, Kim HJ, Huh JW, Do KH, Jang SJ, Song JS, et al. A cluster of lung injury associated with home humidifier use:clinical, radiological and pathological description of a new syndrome. Thorax 2014;69:694-702.

3.

3. Kim HJ, Lee MS, Hong SB, Huh JW, Do KH, Jang SJ, et al. A cluster of lung injury cases associated with home humidifier use: an epidemiological investigation. Thorax 2014;69:703-8.

4.

4. Yang HJ, Kim HJ, Yu J, Lee E, Jung YH, Kim HY, et al. Inhalation toxicity of humidifier disinfectants as a risk factor of children’s interstitial lung disease in Korea: a case-control study. PLoS One 2013;8:e64430.

5.

5. Kim HR, Lee K, Park CW, Song JA, Shin DY, Park YJ, et al. Polyhexamethylene guanidine phosphate aerosol particles induce pulmonary inflammatory and fibrotic responses. Arch Toxicol 2016;90:617-32.

6.

6. Korea Center for Disease Control and Prevention. Interim report of epidemiological investigation on lung injury with unknown cause in Korea [Internet]. Cheongju: Korea Center for Disease Control and Prevention; 2011 [cited 2017 Feb 9]. Available from: http://cdc.go.kr/CDC/cms/content/mobile/00/12700_view.html.

7.

7. Kim KW, Ahn K, Yang HJ, Lee S, Park JD, Kim WK, et al. Humidifier disinfectant-associated children’s interstitial lung disease. Am J Respir Crit Care Med 2014;189:48-56.

8.

8. Paek D, Koh Y, Park DU, Cheong HK, Do KH, Lim CM, et al. Nationwide study of humidifier disinfectant lung injury in South Korea, 1994-2011: incidence and dose-response relationships. Ann Am Thorac Soc 2015;12:1813-21.

9.

9. Park JH, Kim HJ, Kwon GY, Gwack J, Park YJ, Youn SK, et al. Humidifier disinfectants are a cause of lung injury among adults in South Korea: a community-based case-control study. PLoS One 2016;11:e0151849.

10.

10. Lee JH, Kim YH, Kwon JH. Fatal misuse of humidifier disinfectants in Korea: importance of screening risk assessment and implications for management of chemicals in consumer products. Environ Sci Technol 2012;46:2498-500.

11.

11. Park S, Lee K, Lee EJ, Lee SY, In KH, Kim HK, et al. Humidifier disinfectant-associated interstitial lung disease in an animal model induced by polyhexamethylene guanidine aerosol. Am J Respir Crit Care Med 2014;190:706-8.

12.

12. Park DU, Friesen MC, Roh HS, Choi YY, Ahn JJ, Lim HK, et al. Estimating retrospective exposure of household humidifier disinfectants. Indoor Air 2015;25:631-40.

13.

13. Huh JW, Hong SB, Do KH, Koo HJ, Jang SJ, Lee MS, et al. Inhalation lung injury associated with humidifier disinfectants in adults. J Korean Med Sci 2016;31:1857-62.

14.

14. Chang MH, Park H, Ha M, Kim Y, Hong YC, Ha EH. Characteristics of humidifier use in Korean pregnant women: the Mothers and Children’s Environmental Health (MOCEH) study. Environ Health Toxicol 2012;27:e2012003.

15.

15. Koo HJ, Do KH, Chae EJ, Kim HJ, Song JS, Jang SJ, et al. Humidifier disinfectant-associated lung injury in adults: Prognostic factors in predicting short-term outcome. Eur Radiol 2017;27:203-11.

16.

16. Kim WY, Park S, Kim HJ, Chae EJ, Do KH, Huh JW, et al. Lung function in patients with lung injury due to household chemical inhalation: post hoc analysis of a prospective nationwide cohort. Respirology 2017;22:345-51.

17.

17. Kim WY, Kim SW, Jo KW, Choi SH, Kim HR, Kim YH, et al. Lung transplantation for chronic humidifier disinfectantassociated lung injury. Korean J Crit Care Med 2016;31:146-51.

18.

18. Cheon CK, Jin HS, Kang EK, Kim HB, Kim BJ, Yu J, et al. Epidemic acute interstitial pneumonia in children occurred during the early 2006s. Korean J Pediatr 2008;51:383-90.

Tuberculosis & Respiratory Diseases