open access
메뉴ISSN : 0376-4672
The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.
Jemt T, Rubenstein JE, Carlsson L, Lang BR. Measuring fit at the implant prosthodontic interface. J Prosthet Dent 1996;75:314-325
Jimbo R, Halldin A, Janda M, Wennerberg A, Vandeweghe S. Vertical fracture and marginal bone loss of internal-connection implants: a finite element analysis. Int J Oral Maxillofac Implants 2013;28:e171-176
Cha HS, Kim YS, Jeon JH, Lee JH. Cumulative survival rate and complication rates of single-tooth implant; Focused on the coronal fracture of fixture in the internal connection implant. J Oral Rehabil 2013;40:595-602
Branemark P. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410
Watanabe F, Uno I, Hata Y, Neuendorff G, Kirsch A. Analysis of stress distribution in a screw-retained implant prosthesis. Int J Oral Maxillofac Implants 2000;15:209-218
Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-625
Kosyfaki P, del Pilar Pinilla Martin M, Strub JR. Relationship between crowns and the periodontium: a literature update. Quintessence Int 2010;41:109-126.
Katsoulis J, Takeichi T, Sol Gaviria A, Peter L, Katsoulis K. Misfit of implant prosthese and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature. Eur J Oral Implantol 2017;10:121-138
Sharkey S, Kelly A, Houston F, O'Sullivan M, Quinn F, O'connell B. A Radiographic analysis of implant component misfit. Int J oral Maxillofac Implants 2011;26:807-815
Hayashi M, Watts DC, Ebisu S, Wilson NH. Influence of vision on the evaluation of marginal discrepancies in restorations. Oper Dent 2005;30:598-601
Hayashi M, Wilson NH, Ebisu S, Wattts DC. Influence of explorer tip diameter in identifying restoration margin discrepancies. J Dent 2005;33:669-674
Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR. Clinical methods for evaluating implant framework fit. J Prosthet Dent 1999;81:7-13
Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implant in the edentulous jaw: a study of treatment from the time of prostheses placement to the first annual check up. Int J Oral Maxillofac Implants 1991;6:270-276.
Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three dimensional photogrammetric technique. Clin Oral Implants Res 1995;6:172-180
Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: A critical review. Int J Oral Maxillofac Implants 2010;25:506-515
Lee JI, Lee Y, Kim YL, Cho HW. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study. J Prosthet Dent 2016;115:161-169
Lencioni KA, Macedo AP, Silveira Rodrigues RC, Ribeiro RF, Almeida RP. Photoelastic comparison of as-cast and laser-welded implant frameworks. J Prosthet Dent 2015;114:652-659
Lee JI, Lee Y, Kim NY, Kim YL, Cho HW. A photoelastic stress analysis of screw- and cementretained implant prostheses with marginal gaps. Clin Implant Dent Relat Res 2013;15:735-749
de Torres EM, Barbosa GA, Bernardes SR, de Mattos Mda G, Ribeiro RF. Correlation between vertical misfits and stresses transmitted to implants from metal frameworks. J Biomech 2011;44:1735-1739
Termeie D, Klokkevold PR, Caputo AA.. Effect of implant diameter and ridge dimension on stress distribution in mandibular first molar siters-A photoelastic study. J Oral Implantol 2015;41:e165-173
Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-598
Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 2002;11:30-40
Assuncao WG, Gomes EA, Rocha EP, Delben JA. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses. Int J Oral Maxillofac Implants 2011;26:788-796
Dos Santos MB, Zen BM, Bacchi A. Effect of vertical misfit and clip material on stress distribution of overdentures under masticatory loading. Med Biol Eng Comput 2016;54:1515-1521
Winter W, Taylor TD, Karl M. Bone adaptation induced by non-passively fitting implant superstructures: A finite element analysis based on in vivo strain measurements. Int J Oral Maxillofac Implants 2011;26:1288-1295
Brosh T, Pilo R, Sudai D. The influence of abutment angulation on strains and stresses along the implant/bone interface: Comparison between two experimental techniques. J Prosthet Dent 1998;79:328-334
Abduo J, Swain M. Influence of vertical misfit of titanium and zirconia frameworks on peri-implant strain. Int J Oral Maxillofac Implants 2012;27:529-536
De Vasconcellos DK, Ozcan M, Maziero Volpato CA, Bottino MA, Yener ES. Strain gauge analysis of the effect of porcelain firing simulation on the prosthetic misfit of implant-supported frameworks. Implant Dent 2012;21:225-229
Tahmaseb A, Mercelis P, de Clerck R, Wismeijer D. Optical scan analysis to detect minor misfit on implant-supported superstructures. Int J Oral Maxillofac Implants 2011;26:1344-1350
Nascimento Cd, Ikeda LN, Pita MS, Pedroso e Silva RC, Pedrazzi V, Albuquerque RF, Ribeiro RF. Marginal fit and microbial leakage along the implant-abutment interface of fixed partial prosthesis: An in vitro analysis using checkerboard DNA-DNA hybridization. J Prosthet Dent 2015;114:831-838
Teixeira W, Ribeiro RF, Sato S, Pedrazzi V. Microleakage into and from two-stage implants: An in vitro comparative study. Int J Oral Maxillofac Implants 2011;26:56-62
Piattelli A, Scarano A, Paolantonio M, Assenza B, Leghissa GC, Di Bonaventura G, Catamo G, Piccollomini R. Fluids and microbial penetration in the internal part of cement-retained versus screwretained implant-abutment connections. J Periodontol 2001;72:1146-1150
do Nascimento C, Miani PK, Pedrazzi V, Goncalves RB, Ribeiro RF, Faria AC, Macedo AP, de Albuquerque RF Jr. Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions. Int J Oral Maxillofac Implants 2012;27:551-560
Lie A, Jemt T. Photogrammetric measurements of implant positions. Description of a technique to determine the fit between implants and superstructures. Clin Oral Implants Res;5:30-36
Jemt T, Lekholm U. Measurements of bone and frame-work deformations induced by misfit of implant superstructures. A pilot study in rabbits. Clin Oral Implants Res 1998;9:272-280
Chia VA, Esguerra RJ, Teoh KH, Teo JW, Wong KM, Tan KB. In vitro three-dimensional accuracy of digital implant impressions: The effect of implant angulation. Int J Oral Maxillofac Implants 2017;32:313-321
Geramipanah F, Sahebi M, Davari M, Hajimahmoudi M, Rakhshan V. Effects of impression levels and trays on the accuracy of impressions taken from angulated implants. Clin Oral Implants Res 2015;26:1098-1105
Eliasson A, Wennerberg A, Johansson A, Ortorp A, Jemt T. The precision of fit of milled titanium implant frameworks in the edentulous jaw. Clin Implant Dent Relat Res 2010;12:81-90
Alvarez A, Lafita P, de Lianos H, Gago A, Brizuela A, Ellacuria JJ. A comparison of two soldering techniques on the misfit of bar-retained implantsupported overdentures. J Prosthodont 2014;23:163-170
Spazzin AO, Bacchi A, Trevisani A, Farina AP, Dos Santos MB. Fit analysis of defferent framework fabrication techniques for implant-supported partial prostheses. Int J Prosthodont 2016;29:351-353
Katsoulis J, Muller P, Mericske-Stern R, Blatz MB. CAD/CAM fabrication accuracy of long- vs. shortspan implant-supported FDPs. Clin Oral Implants Res 2015;26:245-249
Katsoulis J, Mericske-Stren R, Rotkina L, Zbaren C, Enkling N, Blatz MB. Precision of fit of implantsupported screw-retained 10-unit computer-aided - designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study. Clin Oral Implants Res 2015;26:44-49
Pauwels R, Araki K, Siewerdsen JH, Thongvigitmanee SS. Technical aspects of dental CBCT: state of the art. Dentomaxillofac Radiol 2015;44:20140224
Rodrigues SA, Presotto AGC, Barao VAR, Consani RLX, Nobilo MAA, Mesquita MF. The role of welding techniques in the biomechanical behavior of implant-supported prostheses. Mater Sci Eng C Mater Biol Appl 2017;78:435-442
Meleo D, Baggi L, Di Girolamo M, Di Carlo F, Pecci R, Bedini R. Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis. Ann Ist Super Sanita 2012;48:53-58
Blum K, Wiest W, Fella C, Balles A, Dittmann J, Rack A, Maier D, Thomann R, Spies BC, Kohal RJ, Zabler S, Nelson K. Fatigue induced changes in conical implant-abutment connections. Dent Mater 2015;11:1415-1426
Rack A, Rack T, Stiller M, Riesemeier H, Zabler S, Nelson K. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants. J Synchrotron Radiat 2010;17:289-294