ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

논문 상세

Home > 논문 상세
  • P-ISSN 1010-0695
  • E-ISSN 2288-3339

Study on the Selection of Representative Pulse Wave

대한한의학회지 / Journal of Korean Medicine, (P)1010-0695; (E)2288-3339
2008, v.29 no.5, pp.104-110
김종열 (한국한의학연구원)
신상훈 (상지대학교)
  • 다운로드 수
  • 조회수

Abstract

Objectives:The purpose of this study is to develop the method of selecting representative pulse wave. Methods:The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results:In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions:So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

keywords
representative pulse wave, shape accordance, floating-sinking ratio, pulse height, pulse time


참고문헌

1

1. Tang WC, Sun HJ, Xu JG, Li BF. A study of the traditional chinese pulse simulator system. China Journal of Basic Medicine in Traditional Chinese Medicine 2000; 6(1): 62-65.

2

2. Shin SH, Park YB, Rhim HW, Kim KW. A study of the pulse diagnosis research trend in China. The Journal of the Korea Institute of Oriental Medical Diagnostics 2004; 8(2): 45-56.

3

3. Shin SH, Rhim HW, Park YJ, Park YB. A Study of the cardiovascular aging effect on the pulse shape. The Journal of the Korea Institute of Oriental Medical Diagnostics 2005; 9(1): 59-68.

4

4. Niu X, Yang XZ, Fu CY, Liu ZW, Liu WP. Three-dimensional motion of the radial artery and attributes of position, rhythm, shape and variance of pulse diagnosis. Chinese Journal of Integrated Traditional and Western Medicine 1994; 14(7): 435-437.

5

5. Fei ZF, Zhang ZF. Imagint and quantification of traditional pulse taking. Nature Magazine 1995; 17(5): 27-32.

6

6. Li JT. The objective detection and description of the types of pulse based on the chinese traditional medical science. Chinese Journal of Medical Instrumentation 2001; 25(6): 318-323.

7

7. Wang BH, Yang YX. Experiment Design and Power spectral Characteristics of Pulse Signals. Chinese Journal of Physical Medicine and Retabulitation. 1998; 20(3): 158-161.

8

8. Xu F, Lu Y, Xiao HS. 40 Cases of Determination on Radial Artery Blood Flow of Wiry Pulse and Non-wiry Pulse by CVIQ. Liaoning Journal of Traditional Chinese Medicine 2000; 27(4): 153- 154.

9

9. Huh W, Han SC, Park YB. Feature Point Detection of Radial Pulse Wave. The Journal of the Korea Institute of Oriental Medical Diagnostics 2000; 4(2): 66-70.

10

10. Nichols WW, O’Rourke MF. McDonald’s blood flow in arteries. 5th ed. London: Edward Arnold. 1998: 193-213.

11

11. Shin SH. A study of analytical model for the pulse formation mechanism. Ph.D. Thesis, Kyunghee University. 2006: 49-60. (910)

상단으로 이동

대한한의학회지