open access
메뉴ISSN : 0376-4672
SFI-bar is prefabricated bar system and can be assembled at chairside without soldering or welding, thus reducing bone loss, costs and time. A 53-year-old male patient, who had severely absorbed mandible, hoped to wear a stable mandiblular denture. Four implants were placed in the extraction site of canine and 1st molar. Early loaded temporary denture with solitary type attachment was delivered 3 weeks after surgery. 3 month later, SFI-bar was connected and adjusted at chairside. Then, implant overdenture using SFI-bar was delivered. This case report showed that a satisfactory clinical result was achieved by 4-implantsupported overdenture using the SFI-Bar system in a mandibular edentulous patient.
Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc 2003; 134:1455-8.
Branemark PI, Adell R, Breine U, Hansson BO, Undstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969; 3:81-100.
DeBoer J. Edentulous implants: overdenture versus fixed. J Prosthet Dent 1993; 69:386-90.
Misch CE. Contemporary implant dentistry. 2nd edition. Missouri CV Mosby. 67-72. 1999.
Budtz-Jaraensen E. Restoration of the partially edentulous mouth - a comparison of overdentures, removable partial dentures, fixed partial dentures and implant treatment J Dent. 1996 Jul; 24(4):237-44.
Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416
Sadowsky SJ. Mandibular implant-retained overdentures: A literature review. J Prosthet Dent 2001; 86:468-73.
Takeshita S, Kanazawa M, Minakuchi S. Stress analysis of mandibular two-implant overdenture with different attachment systems. Dent Mater J 2011; 30:928-34.
Van Kampen F, Cune M, Van der Bilt A, Bosman F. Retention and post insertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003; 14:720-6.
Kim HY, Kim RJ, Qadeer S, Jeong CM, Shin SW, Huh JB. Immediate loading on mandibular edentulous patient with SFI Bar overdenture. J Adv Prosthodont 2011; 3:47-50.
Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc 2003; 134:1455-8.
Hamid RS. Clinical and Laboratory Manual of Implant Overdentures. Wiley-Blackwell. 2006; 32.
Seung-Ryong Ha, Sung-Hun Kim, Seung-Il Song, Seong-Tae Hong, Gy-Young Kim. Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient J Adv Prosthodont 2012; 4:254-8.
Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology 2002; 19:3-4.
Vercruyssen M, Marcelis K, Coucke W, Naert I, Quirynen M. Long-term, retrospective evaluation (implant and patient-centred outcome) of the two-implants-supported overdenture in the mandible. Part 1: survival rate. Clin Oral Implants Res 2010; 21:357-65.
Thomason JM, Kelly SA, Bendkowski A, Ellis JS. Two implant retained overdentures-a review of the literature supporting the McGill and York consensus statements. J Dent 2012; 40:22-34.
Neill DJ. The problem of the lower free-end removable partial denture. J Prosthet Dent 1958; 8:623-34.
Meijer HJ, Starmans FJ, Steen WH, Bosman F. A three-dimensional finite element study on two versus four implants in an edentulous mandible. Int J Prosthodont 1994; 7:271-9.
Hong JW, Ahn SG, Leem DH, Seo JM. Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report. J Adv Prosthodont 2012; 4:52-6.
Brunski JB. Biomechanical factors affecting the bone-dental implant interface. Clin Mater. 1992; 10(3):153-201.
Lum, LB, Beirne, OR, Curtis, DA. Histologic evaluation of hydroxyapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications. Int J Oral Maxillofac Implants. 1991; 6:456-462.
Balshi TJ, Wolfinger GJ. Immediate loading of Branemark implants in edentulous mandibles: a preliminary report. Implant Dent. 1997 Summer; 6(2):83-8.
Carl E. Misch, Martha W Bidez, Kenneth WM Judy, Louis T Kircos, Roland Meffert, Craig M Misch. Dental implant prosthetics. Elsevier Inc. 547. 2005.
Lorenzoni M, Pertl C, Zhang K, Wimmer G, Wegscheider WA. Immediate loading of single-tooth implants in the anterior maxilla. Preliminary results after one year. Clin Oral Implant Dent Relat Res. 2000; 2:138-146.