바로가기메뉴

본문 바로가기 주메뉴 바로가기

Journal of the Korean Association of Oral and Maxillofacial Surgeons

  • P-ISSN2234-7550
  • E-ISSN2234-5930
  • SCOPUS, KCI, ESCI

Comparison of accuracy between panoramic radiography, cone-beam computed tomography, and ultrasonography in detection of foreign bodies in the maxillofacial region: an in vitro study

Journal of the Korean Association of Oral and Maxillofacial Surgeons / Journal of the Korean Association of Oral and Maxillofacial Surgeons, (P)2234-7550; (E)2234-5930
2018, v.44 no.1, pp.18-24
Mehrdad Abdinian (Isfahan University)
Maedeh Aminian (Isfahan University)
Samad Seyyedkhamesi (Islamic Azad University)

Abstract

Objectives: Foreign bodies (FBs) account for 3.8% of all pathologies of the head and neck region, and approximately one third of them are missed on initial examination. Thus, FBs represent diagnostic challenges to maxillofacial surgeons, rendering it necessary to employ an appropriate imaging modality in suspected cases.Materials and Methods: In this cross-sectional study, five different materials, including wood, metal, glass, tooth and stone, were prepared in three sizes (0.5, 1, and 2 mm) and placed in three locations (soft tissue, air-filled space and bone surface) within a sheep’s head (one day after death) and scanned by panoramic radiography, cone-beam computed tomography (CBCT), and ultrasonography (US) devices. The images were reviewed, and accuracy of the detection modalities was recorded. The data were analyzed statistically using the Kruskal-Wallis, Mann-Whitney U-test, Friedman, Wilcoxon signed-rank and kappa tests (P<0.05). Results: CBCT was more accurate in detection of FBs than panoramic radiography and US (P<0.001). Metal was the most visible FB in all of mo-dalities. US was the most accurate technique for detecting wooden materials, and CBCT was the best modality for detecting all other materials, regard-less of size or location (P<0.05). The detection accuracy of US was greater in soft tissue, while both CBCT and panoramic radiography had minimal accuracy in detection of FBs in soft tissue.Conclusion: CBCT was the most accurate detection modality for all the sizes, locations and compositions of FBs, except for the wooden materials. Therefore, we recommend CBCT as the gold standard of imaging for detecting FBs in the maxillofacial region.

keywords
Foreign bodies, Panoramic radiography, Cone-beam computed tomography, Ultrasonography, Maxillofacial region

Journal of the Korean Association of Oral and Maxillofacial Surgeons