바로가기메뉴

본문 바로가기 주메뉴 바로가기

ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

Journal of the Korean Association of Oral and Maxillofacial Surgeons

  • P-ISSN2234-7550
  • E-ISSN2234-5930
  • SCOPUS, KCI, ESCI

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

Journal of the Korean Association of Oral and Maxillofacial Surgeons / Journal of the Korean Association of Oral and Maxillofacial Surgeons, (P)2234-7550; (E)2234-5930
2020, v.46 no.2, pp.133-142
https://doi.org/10.5125/jkaoms.2020.46.2.133
Ki-Young Lee (Wonkwang University)
Kyung Su Shin (Wonkwang University)
Ji-Hye Jung (Wonkwang University)
Hye-Won Cho (Wonkwang University)
Kyung-Hwan Kwon (Wonkwang University)
Yu-Lee Kim (Wonkwang University)

Abstract

Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant–abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant–abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant–abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.

keywords
Dental implants, Screw loosening, Regression analysis

Journal of the Korean Association of Oral and Maxillofacial Surgeons