open access
메뉴ISSN : 0376-4672
Treatment with removable partial denture is effective for partially edentulous patients who are unable to obtain sufficient retention and stability for functional and esthetic restoration. There are several cases reporting the improvement of retention and stability of the partial denture using a small number of implants. However, there are limited studies on the implant-assisted removable partial denture using a small number of remaining teeth and the bar locator system. The bar locator system has an advantage in that it could compensate the angle of insertion of removable prosthesis on implant with inconsistent placement angle due to anatomical constraints compared to when using the locator only. This case report describes the patient with Parkinson°Øs disease who was treated with the Locator bar system using two previously placed implants and two remaining teeth on maxilla. No additional implants could be placed because of the medical and economic condition of the patients, and the angle of one of two implants could not be matched with the direction of the removable partial denture insertion. Considering the angle of the implants, the patient was treated with implant-assisted RPD using the Locator bar system and had satisfactory results in the aspect of esthetics, masticatory function, and oral hygiene maintenance.
1. Budtz-Jörgensen E. Restoration of the partially edentulous mouth-a comparison of overdentures, removable partial dentures, fixed partial dentures and implant treatment. J Dent 1996; 24:237-244.
2. Mijiritsky E, Karas S. Removable partial denture design involving teeth and implants as an alternative to unsuccessful fixed implant therapy: a case report. Implant Dent 2004; 13:218-222.
3. Chikunov I, Doan P, Vahidi F. Implant?Retained Partial Overdenture with Resilient Attachments. J Prosthodont 2008; 17:141-148.
4. de Carvalho WR, Barboza EP, Ca?la AL. Implantretained removable prosthesis with ball attachments in partially edentulous maxilla. Implant Dent 2001; 10:280-284.\
5. Bortolini S, Natali A, Franchi M, Coggiola A, Consolo U. Implant-retained removable partial dentures: an 8-year retrospective study. J Prosthodont 2011; 20:168-172.
6. Renouard F, Nisand D. Short implants in the severely resorbed maxilla: a 2-year retrospective clinical study. Clin Implant Dent Relat Res. 2005; 7:104-110.
7. Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent. 2006; 15:24-34.
8. Kim MS, Yoon MJ, Huh JB, Jeon YC, Jeong CM. Implant overdenture using a locator bar system by drill and tapping technique in a mandible edentulous patient: a case report. J Adv Prosthodont 2012; 4:116-120.
9. Han KH, Lee JY, Shin SW. Implant- and Tooth-Supported Fixed Prostheses Using a High-Performance Polymer (Pekkton) Framework. Int J Prosthodont. 2016; 29:451-454.
10. Emami E, Heydecke G, Rompré PH, de Grandmont P, Feine JS. Impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: a metaanalysis of randomized-controlled trials. Clin Oral Implants Res 2009; 20:533-544.
11. Ohkubo C, Kobayashi M, Suzuki Y, Hosoi T. Effect of Implant Support on Distal-Extension Removable Partial Dentures: In Vivo Assessment. Int J Oral Maxillofac Implants 2008; 23:1095-1101.
12. Mijiritsky E, Karas S. Removable partial denture design involving teeth and implants as an alternative to unsuccessful fixed implant therapy: a case report. Implant Dent 2004; 13:218-222.
13. Chikunov I, Doan P, Vahidi F. Implant-Retained Partial Overdenture with Resilient Attachments. J Prosthodont 2008; 17:141-148.