ISSN : 2233-8292
최근 유럽 및 일본에서는 강섬유 보강 콘크리트를 활용하여 철근을 생략하거나 최소화하기 위한 연구가 수행중에 있으며, 세그먼트 제작시 강섬유 보강 콘크리트 활용은 철근 생략 또는 최소화를 통한 경제성 향상은 물론 품질관리 향상효과가 있는 것으로 알려져 있다. 따라서 본 연구에서는 강섬유 보강효과 검토를 위하여 기존에 널리 활용되고 있는 철근만으로 보강된 세그먼트와 철근 및 강섬유로 보강된 세그먼트 실험체 제작 및 휨실험을 수행하였다. 실험결과 세그먼트 강섬유 보강은 콘크리트의 연성 증가효과로 인하여 균열제어는 물론 기존 세그먼트 보강재인 철근의 대체할 수 있는 보강재로 활용이 가능할 것으로 판단된다.
An experimental research on the possibility of using fiber reinforced concrete precast tunnel segments instead of traditional reinforced concrete(RC) segment has been performed in europe. This solution allows removing the traditional reinforcement with several advantages in terms of quality and cost reduction. Full-scale bending tests were carried out in order to compare the behaviour of the segments under flexural actions on both rebar reinforced concrete and rebar-fiber reinforced elements. The test results showed that the fiber reinforced concrete can substitute the traditional reinforcement; in particular the segment performance is improved by the fiber presence, mainly in terms of crack.
1. Lee, G.P., Park, Y.T., Choi, S.W., Chang, S.H., Bae, G.J., Kang, T.S., Lee, J.S. (2012), “An experimental study on mechanical behavior of shield segment with high-strength concrete and high-tension rebar”, Journal of the Korean Tunnelling Association, Vol. 14, No. 3, pp. 215-230.
2. Albert, de la F., Pablo, P., Ana, B., Antonio, A. (2012), “Experiences in barcelona with the use of fibres in segmental linings”, Tunnelling and Underground Space Technology, Vol. 27, Issue 1, pp. 60-71.
3. Moon, D.Y., Lee, G.P., Chang, S.H., Bae, G.J. (2011), “Effect of steel fibers on surface resistivity of steel fiber reinforced concrete for shield segment”, Journal of the Korean Tunnelling Association, Vol. 13, No. 6, pp. 557-569.
4. Kim, B.K., Lee, J.S., Lee, G.P., Chang, S.H., Bae, G.J. (2011), “Mechanical characteristics of high-performance concrete shield segment containing ground granulated blast furnace slag and their improvement by steam curing”, Journal of the Korean Tunnelling Association, Vol. 13, No. 3, pp. 233-242.
5. Angelo, C., Alberto, M., Zila, R., Paolo, R. (2011), “Structural behaviour of precast tunnel segments in fiber reinforced concrete”, Tunnelling and Underground Space Technology, Vol. 26, Issue 2, pp. 284-291.
6. Shin, J.H., Shin, Y.S., Park, D.I., Chae, S.E., Choi, K.H. (2009), “A study on hydraulic behaviour and leakage control of segment linings using the numerical methods”, Journal of the Korean Tunnelling Association, Vol. 11, No. 2, pp. 131-140.
7. Bernardino, C., Alessandro, P.F., Paolo, V. (2009), “Combining fiber-reinforced concrete with traditional reinforcement in tunnel linings”, Engineering Structures, Vol. 31, Issue 7, pp. 1600-1606.
8. Jeon, J.K., Jeon, C.K., Kim, N.Y., Kim, S.M., Lee, J.E. (2006), “A study on controllong of cracks occurred at crown of tunnel concrete lining using model test”, Journal of the Korean Tunnelling Association, Vol. 8, No. 3, pp. 227-235.
9. Oh, B.H. (1991), “A theoretical and experimental investigation on the flexural behavior of reinforced concrete members containing steel fibers”, Journal of the Korea Concrete Institute, Vol. 3, No. 3, pp. 129-139.
10. Lee, G.P., Park, Y.T., Choi, S.W., Chang, S.H., Bae, G.J., Lee, J.S., Kang, T.S. (2012), “Evaluation of high-performance segment by full scale bending test”, Proceeding of the 13th KTA international symposium on mechanized tunnelling technology, pp. 93-102.
11. Seo, S.Y., Ha, H.S., Lee, S.P. (2011), “Use of steel fiber, macro synthetic fiber and glass fiber in a segmental lining”, Proceeding of the 12th KTA international symposium on mechanized tunnelling technology, pp. 123-128.
12. Gettu, R., Barragán, B., García, T., Ramos, G., Fernández C., Oliver, R. (2004), “Steel fiber reinforced concrete for the Barcelona Metro Ling 9 tunnel lining”, Proc. of the 6th RILEM Symposium on FRC, Varenna, Italy, RILEM PRO 39, pp. 141-156.