국내 석탄광 분진의 특성과 효율적 제어

Characteristics of domestic coals and efficient control of coal dust

(사)한국터널지하공간학회 / (사)한국터널지하공간학회, (P)2233-8292; (E)2287-4747
2017, v.19 no.4, pp.589-609
https://doi.org/10.9711/KTAJ.2017.19.4.589
김수홍 (한국농어촌공사 경남지역본부 지하수지질부)
권준욱 ((주)지오미래이앤씨 기업부설연구소장)
김선명 (신한대학교)
김윤광 ((주)굿엔지니어스 연구소)
장윤호 (강원대학교)

Abstract

This study carried out the density and energy dispersive X-ray spectroscopy and particle size analysis which are the physical characteristics of coal dust by collecting samples of coal dust in the five domestic mines to control the coal dust through ventilation in the workplace for coal mining in the country. This will contribute to a more comfortable working environment by understanding the physical characteristics of the coal dust which is derived from any hard coal produced domestically. In particular, the result of PSA analysis showed that the size of coal dust sample for this study ranged from 0.007~88.614 μm were the particles less than 3.5 μm, the size range responsible for pneumoconiosis. To observe the flow of coal dust collected on the wind speed, the fallout of coal dust produced by the wind tunnel for the wind was measured and the particle size analysis of coal dust fallout was carried out. In addition, airborne dust is measured according to the mine velocity by using a multi-stage Anderson sampler in the mine where fine dust is generated in a large amount and the wind speed is found out to control the coal dust below 3.5 μm. In addition, natural ventilation pressure of A mine was calculated to prevent over design of the main fan.

keywords
석탄분진, 입도, 자연환기력, 풍동, 석탄광산, Coal dust, Grain size, Natural ventilation force, Wind tunnel, Coal mining

참고문헌

1.

1. Hartman, H.L. (1982), “Mine ventilation and air conditioning(second edition)”, A WILEY- INTERSCIENCE PUBLICATION.

2.

2. Kim, H.G., Choi, P.G., Ryu, J.O., Lee, C.W. (2016), “A fundamental study on the ventilation analysis method for network-type tunnel-focused on the none hardy-cross method”, Journal of Korean Tunnelling and Underground Space Association, Vol. 18, No 03, pp. 291-303.

3.

3. Kim, H.G., Yoo, J.O., Lee, C.W. (2014), “A study on applications of the natural ventilation pressure(NVP)in local tunnels”, Journal of Korean Tunnelling and Underground Space Association, Vol. 16, No 03, pp. 269-285.

4.

4. Kim, Y.K. (2000), “Study on the Improvement of Ventilation System in Jang-Sung Colliery”, Journal of the Korean Institute of Mineral and Energy Resources Engineers, Vol. 37, No. 3, pp. 173-180.

5.

5. Lee, C.W., Kim, S.H., Gil, S.W., Cho, W.C. (2009), “A case study for prediction of the natural ventilation force in a local long vehicle tunnel”, Journal of Korean Tunnelling and Underground Space Association, Vol. 11, No 4, pp. 395-401.

6.

6. McPherson, M.J. (1987), “The resistance to airflow of mine shafts”, Mine Ventilation Society of South Africa.

7.

7. McPherson, M.J. (1993), “Surface ventilation and environmental engineering”, Chapman & Hall, pp. 134-141.

8.

8. Sinha (1982), What's Needed to Win the War against Black Lung Diesease, Coal Min. & Proc., May, pp. 63-68.

9.

9. Zheng, G.Q., Ramani, K. (1989), Generation and Entrainment of Coal Dust Underground Mines, Proc. 4th U.S. Mine Vent. Sympo., SME, Littleton, CO, pp. 454-461.

(사)한국터널지하공간학회