ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Feasibility Study of Isotope Ratio Analysis of Individual Uranium-Plutonium Mixed Oxide Particles with SIMS and ICP-MS

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2011, v.2 no.4, pp.80-83
https://doi.org/10.5478/MSL.2011.2.4.080
Fumitaka Esaka (Japan Atomic Energy Agency)
Masaaki Magara (Japan Atomic Energy Agency)
Daisuke Suzuki (Japan Atomic Energy Agency)
Yutaka Miyamoto (Japan Atomic Energy Agency)
Chi-Gyu Lee (Japan Atomic Energy Agency)
Takaumi Kimura (Japan Atomic Energy Agency)
  • 다운로드 수
  • 조회수

Abstract

Isotope ratio analysis of nuclear materials in individual particles is of great importance for nuclear safeguards. Although secondary ion mass spectrometry (SIMS) and thermal ionization mass spectrometry (TIMS) are utilized for the analysisof individual uranium particles, few studies were conducted for the analysis of individual uranium-plutonium mixed oxide particles. In this study, we applied SIMS and inductively coupled plasma mass spectrometry (ICP-MS) to the isotope ratio analysis of individualU-Pu mixed oxide particles. In the analysis of individual U-Pu particles prepared from mixed solution of uranium and plutoniumstandard reference materials, accurate 235U/238U, 240Pu/239Pu and 242Pu/239Pu isotope ratios were obtained with both methods. However, accurate analysis of 241Pu/239Pu isotope ratio was impossible, due to the interference of the 241Am peak to the 241Pupeak. In addition, it was indicated that the interference of the 238UH peak to the 239Pu peak has a possibility to prevent accurateanalysis of plutonium isotope ratios. These problems would be avoided by a combination of ICP-MS and chemical separation ofuranium, plutonium and americium in individual U-Pu particles.

keywords
SIMS, ICP-MS, Isotope ratio, Uranium, Plutonium


참고문헌

1

Donohue, D. L.. (1998). . J. Alloys Compd, 11, 271-.

2

Donohue, D. L. (2002). . Anal. Chem, 74, 28A-.

3

Simons, D. S.. (1998). Secondary Ion Mass Spectrometry XI:John Wiley & Sons.

4

Tamborini, G.. (1998). . Spectrochim. Acta B, 53, 1289-.

5

Esaka, F.. (2007). . Talanta, 71, 1011-.

6

Esaka, F. (2009). . Talanta, 78, 290-.

7

Ranebo, Y.. (2009). . J. Anal. At. Spectrom, 24, 277-.

8

Hedberg, P. M. L. (2011). . J. Anal. At. Spectrom, 26, 406-.

9

Lee, C. G.. (2007). . J. Radioanal. Nucl. Chem, 272, 299-.

10

Lee, C. G. (2009). . J. Nucl. Sci. Technol, 46, 809-.

11

Sujin Park. (2011). Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique. Mass Spectrometry Letters, 2(2), 57-60. http://dx.doi.org/10.5478/MSL.2011.2.2.057.

12

Kraiem, M.. (2011). . Anal. Chem, 83, 3011-.

13

Simons, D. S. (1992). Secondary Ion Mass Spectrometry VIII:John Wiley & Sons.

14

Esaka, F.. (2010). . Talanta, 83, 569-.

15

Ranebo, Y.. (2010). . Betti, M. Anal. Chem, 82, 4055-.

16

Wellum, R.. (2009). . J. Anal. At. Spectrom, 24, 801-.

투고일Submission Date
2011-11-22
수정일Revised Date
2011-11-29
게재확정일Accepted Date
2011-11-29
상단으로 이동

Mass Spectrometry Letters