- P-ISSN 2233-4203
- E-ISSN 2093-8950
Microfluidic technologies hold high promise and emerge as a potential molecular tool to facilitate the progress of fundamental and applied biomedical researches by enabling miniaturization and upgrading current biological research tools. In this review, we summarize the state of the art of existing microfluidic technologies and its’ application for characterizing bio- physical properties of individual cells. Microfluidic devices offer significant advantages and ability to handle in integrating sam- ple processes, minimizing sample and reagent volumes, and increased analysis speed. Therefore, we first present the basic concepts and summarize several achievements in new coupling between microfluidic devices and mass spectrometers. Secondly, we discuss the recent applications of microfluidic chips in various biological research field including cellular and molecular level. Finally, we present the current challenge of microfluidic technologies and future perspective in this study field.
Kakac S.. (2010). Microfluidics Based Microsystems:Springer.
Andersson, H.. (2003). . Sens. Actuator B Chem., 92, 315-. http://dx.doi.org/10.1016/S0925-4005(03)00266-1.
Zhuang, Q. -C.. (2016). . Chinese J. Anal. Chem., 44, 522-. http://dx.doi.org/10.1016/S1872-2040(16)60919-2.
Bange, A.. (2005). . Biosens. Bioelectron., 20, 2488-. http://dx.doi.org/10.1016/j.bios.2004.10.016.
Livak-Dahl, E.. (2011). . Annu Rev. Chem. Biomol. Eng., 2, 325-. http://dx.doi.org/10.1146/annurev-chembioeng-061010-114215.
Rios, A.. (2006). . TrAC-Trends Anal. Chem., 25, 467-. http://dx.doi.org/10.1016/j.trac.2005.11.012.
Loo, J. A.. (2005). . J. Am. Soc. Mass Spectrom., 16, 998-. http://dx.doi.org/10.1016/j.jasms.2005.02.017.
Li, D. (2008). Encyclopedia of Microfluidics and Nanofluidics:Springer.
Kovarik, M. L.. (2011). . Anal. Chem., 84, 516-.
Meyvantsson, I.. (2008). . Annu. Rev. Anal. Chem., 1, 423-. http://dx.doi.org/10.1146/annurev.anchem.1.031207.113042.
Zare, R. N.. (2010). . Annu. Rev. Biomed. Eng., 12, 187-. http://dx.doi.org/10.1146/annurev-bioeng-070909-105238.
Chang, C. -C.. (2007). . Microfluid. Nanofluid., 3, 501-. http://dx.doi.org/10.1007/s10404-007-0178-z.
Posthuma-Trumpie, G. A.. (2009). . Anal. Bioanal. Chem., 393, 569-. http://dx.doi.org/10.1007/s00216-008-2287-2.
Choi, K.. (2012). . Annu. Rev. Anal. Chem., 5, 413-. http://dx.doi.org/10.1146/annurev-anchem-062011-143028.
Fair, R. B.. (2007). . Microfluid. Nanofluid., 3, 245-. http://dx.doi.org/10.1007/s10404-007-0161-8.
Cho, S. K.. (2003). . J. Microelectromech. Syst., 12, 70-. http://dx.doi.org/10.1109/JMEMS.2002.807467.
Nelson, W. C.. (2012). . J. Adhes. Sci. Technol., 26, 1747-.
Wang, Y. -X.. (2004). . LabChip, 4, 363-.
Lee, J.. (2008). . J. Am. Soc. Mass Spectrom., 19, 964-. http://dx.doi.org/10.1016/j.jasms.2008.03.015.
Yang, H.. (2008). . Anal. Chem., 81, 1061-.
Valones, M. A. A.. (2009). . Braz. J. Microbiol., 40, 1-. http://dx.doi.org/10.1590/S1517-83822009000100001.
Fernandes, T. G.. (2009). . Trends Biotechnol., 27, 342-. http://dx.doi.org/10.1016/j.tibtech.2009.02.009.
Grant, S. C.. (2000). . Magn. Reson. Med., 44, 19-. http://dx.doi.org/10.1002/1522-2594(200007)44:1<19::AID-MRM4>3.0.CO;2-F.
Lucas, L. J.. (2006). . Colloids Surf. B Biointerfaces, 49, 106-. http://dx.doi.org/10.1016/j.colsurfb.2006.03.008.
Prest, J. E.. (2008). . Meas. Sci. Technol., 19, 065801-. http://dx.doi.org/10.1088/0957-0233/19/6/065801.
Chabert, M.. (2008). . Proc. Natl. Acad. Sci. U.S.A., 105, 3191-. http://dx.doi.org/10.1073/pnas.0708321105.
Williams, D. F.. (2006). The Biomaterials: Silver Jubilee Compendium:Elsevier Science.
Gomez-Sjoberg, R.. (2005). . J. Microelectromech. Syst., 14, 829-. http://dx.doi.org/10.1109/JMEMS.2005.845444.
Fesenko, D.. (2005). . Biosens. Bioelectron., 20, 1860-. http://dx.doi.org/10.1016/j.bios.2004.06.005.
Floriano, P. N.. (2007). Microchip-Based Assay Systems:Humana Press.
Zguris, J. C.. (2005). . Biomed. Microdevices, 7, 117-. http://dx.doi.org/10.1007/s10544-005-1589-9.
Yoo, S. K.. (2007). . Biosens. Bioelectron., 22, 1586-. http://dx.doi.org/10.1016/j.bios.2006.07.014.
Liu, S.. (2000). . Proc. Natl. Acad. Sci. U.S.A., 97, 5369-. http://dx.doi.org/10.1073/pnas.100113197.
Carrilho, E.. (2000). . Electrophoresis, 21, 55-. http://dx.doi.org/10.1002/(SICI)1522-2683(20000101)21:1<55::AID-ELPS55>3.0.CO;2-I.
Larsen, M. R.. (2005). . Mol. Cell. Proteomics, 4, 873-. http://dx.doi.org/10.1074/mcp.T500007-MCP200.
McNulty, D. E.. (2008). . Mol. Cell. Proteomics, 7, 971-. http://dx.doi.org/10.1074/mcp.M700543-MCP200.
Stensballe, A.. (2001). . Proteomics, 1, 207-. http://dx.doi.org/10.1002/1615-9861(200102)1:2<207::AID-PROT207>3.0.CO;2-3.
Jonsson, M.. (2006). . J. Micromech. Microeng., 16, 2116-. http://dx.doi.org/10.1088/0960-1317/16/10/027.
Mok, J.. (2014). . Proc. Natl. Acad. Sci. U.S.A., 111, 2110-. http://dx.doi.org/10.1073/pnas.1323998111.
Jones, J.. (2005). . Biochim. Biophys. Acta-General Subjects, 1726, 121-. http://dx.doi.org/10.1016/j.bbagen.2005.07.003.
Ninonuevo, M. R.. (2007). . J. Agric. Food Chem., 56, 618-.
Kim, M.. (2008). . Biochem. Biophys. Res. Commun., 365, 628-. http://dx.doi.org/10.1016/j.bbrc.2007.11.020.