ISSN : 2233-8292
The objective of this study is to develop the laboratory testing method for evaluating the loading capacity of lattice girder used for support in tunnel structure. 3-point flexible strength test and 4-point flexible strength test were performed on three types of lattice girder, such as LG-50×20×30, LG-70×20×30, and LG-95×22×32, mainly used in Korea. Two types of loading position for each flexible strength test were used to analyze the behavior of load-deformation. The loading distribution in the lattice girder was analyzed by means of strains measured by strain gauges attached on chords and diagonal bars. In 3-point flexible strength test, the difference of the average of maximum flexible strength according to loading position had the range from 10% to 33%. In 4-point flexible strength test, the average of maximum flexible strength according to loading position was almost no difference. The difference between the average of maximum flexible strengths obtained from 3-point and 4-point flexible strength tests was from 13.56 to 31.55%. The load applied on the lattice girder was concentrated to the main chord in 3-point flexible strength test. The load applied on the lattice girder in 4-point flexible strength test was distributed to three chords and diagonal bars.
김동규, (2007) 레티스거더 성능평가 를 위한 실내시험기법의 평가, 2007 한국지반공학회 가을학술발표회 논문집
문홍득, (1997) 격자지보의 터널지보재의 특성 및 현장 적용성 평가,
(1996) 한국건설기술연구원 , 터널지보용 래티스거더의 현장적용성 연구, 천원공업(주).,
Baumann, T, (1984) Investigation of the performance of lattice girders in tunnelling, Rock Mechanics and Rock Engineering