ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise- Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise- Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2018, v.9 no.1, pp.30-36
https://doi.org/10.5478/MSL.2017.9.1.30
Jaeick Lee (Korea Institute of Science and Technology)
Seunghwa Lee (Korea Institute of Science and Technology)
Byungjoo Kim (Research Institute for Natural Sciences)
Joonhee Lee (Research Institute for Natural Sciences)
Oh-Seung Kwon (Korea Institute of Science and Technology)
Eunju Cha (Daegu-Gyeongbuk Medical Innovation Foundation)
  • 다운로드 수
  • 조회수

Abstract

A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxida- tion of a serum sample (50 µL), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile con- taining 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column (50 mm × 3 mm, 3 µm) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was 0.5- 4.0 µg/mL and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

keywords
Amino acid, mixed-mode chromatography, quantitation, serum, LC-ESI/MS/MS


참고문헌

1

Qu, J.. (2002). . Anal. Chem., 74, 2034-. http://dx.doi.org/10.1021/ac0111917.

2

Wu, G.. (2009). . Amino acids, 37, 1-.

3

Thiele, B.. (2012). . Methods. Mol. Biol., 828, 317-.

4

Thiele, B.. (2008). . Anal. Bioanal. Chem., 391, 2663-. http://dx.doi.org/10.1007/s00216-008-2167-9.

5

Armstrong, M.. (2007). . Rapid Commun. Mass Spectrom., 21, 2717-. http://dx.doi.org/10.1002/rcm.3124.

6

Le, A.. (2014). . J. Chromatogr. B, 944, 166-. http://dx.doi.org/10.1016/j.jchromb.2013.11.017.

7

Choi, M. S.. (2017). . J. Pharm. Biomed. Anal., 145, 5-.

8

Food and Drug Administration. (2001). Guidance for industry: Bioanalytical Method Validation. https://www.fda.gov/downloads/Drugs/Guidance/ucm070107.pdf.

투고일Submission Date
2018-03-07
수정일Revised Date
2018-03-13
게재확정일Accepted Date
2018-03-13
상단으로 이동

Mass Spectrometry Letters