ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2011, v.2 no.2, pp.57-60
https://doi.org/10.5478/MSL.2011.2.2.057
Sujin Park (Korea Atomic Energy Research Institute)
Jong-Ho Park (Korea Atomic Energy Research Institute)
Myung Ho Lee (Korea Atomic Energy Research Institute)
Kyuseok Song (Korea Atomic Energy Research Institute)
  • 다운로드 수
  • 조회수

Abstract

As background significantly affects measurement accuracy and a detection limit in determination of the traceamounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements bythermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes ofthe blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uraniumbackground with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from50 × 50 μm2 to 300 × 300 μm2. Based on the determination of the uranium background in the Lexan film, any background correctionis necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissectedwith less than 300 × 300 μm2 size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carriedout to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.

keywords
Uranium, Background, TIMS, Particle Analysis, Isotopic Analysis, Safeguards


참고문헌

1

Donohue, D. L.. (1998). . J. Alloy Compd, 271-273, 11-.

2

Lee, C. G. (2006). . Jpn. J. Appl. Phys, 45, 294-.

3

Esaka, K. T. (2004). . Jpn, J. Appl. Phys, 43, L915-.

4

Lee, M. H. (2011). . Radiat. Meas, 46, 409-.

5

Shen, Y. (2008). . Radiat. Meas, 43, S299-.

6

Lee, C. G.. (2007). . J. Radioanal. Nucl. Chem, 272, 299-.

7

Lee, M. H.. (2005). . Radiat. Meas, 40, 37-.

8

Cohen, A. S.. (1992). . Int. J. Mass Spectrom. Ion Process, 116, 71-.

9

Heumann, K. G.. (1995). . Analyst, 120, 1291-.

10

Rubin, K. H. (2001). . Chemical Geology, 175, 723-.

11

Richter, S.. (2003). . Int. J. Mass Spectrom, 229, 181-.

12

Suzuki, D.. (2010). . Int. J. Mass Spectrom, 294, 23-.

13

Jeon, Y. S. (2008). . Analytical Science and Technology, 21, 487-.

14

Wolff, J. C.. (1996). . Int. J. Mass Spectrom. Ion Process, 156, 67-.

15

Heumann, K. G.. (1982). . Int. J. Mass Spectrom. Ion Phys, 45, 87-.

16

Suzuki, D.. (2010). . Int. J. Mass. Spectrom, 294, 23-.

17

Kraiem, M.. (2011). . Anal. Chim. Acta, 688, 1-.

투고일Submission Date
2011-06-01
수정일Revised Date
2011-06-07
게재확정일Accepted Date
2011-06-08
상단으로 이동

Mass Spectrometry Letters