open access
메뉴ISSN : 0376-4672
The mini-tube appliance (MTA) is comfortable and advantageous in terms of aesthetics and oral hygiene compared to conventional brackets. By using 0.012 inch Thermoactive (TA) NiTi wires, the frictional resistance is low. So treatment are possible within a short period and there are fewer side effects, such as root resorption. Light-force orthodontic treatment using MTA and thin TA NiTi wire is a suitable treatment method in pediatric dentistry, considering the increasing aesthetic needs and the nature of pediatric patients. By using the MTA and thin TA NiTi wire, the cases reported here have led to posi tive treatment outcomes in minor orthodontic treatment for the anterior teeth crowding and retreatment following relapse after orthodontic treatment.
1. Choi EJ, Jung TR, Kim CC, Kim YJ. The changes in practice pattern and patient distribution for the last 5 years (2000-2005) in the department of pediatric dentistry at seoul national university dental hospital. J Korean Acad Pediatr Dent. 2006;33:673-677.
2. Son YJ, Hyun HK, Kim YJ, Kim JW, Lee SH, Kim JC et al. The changes in practice patterns for the last 8 years (2001-2008) in the department of pediatric dentistry, seoul national university dental hospital. J Korean Acad Pediatr Dent. 2010;37:97-101.
3. Baik HS, Hwang CJ, Kim KH, Yu HS, Kim TK. Contemporary removable Orthodontics. 2nd ed. Seoul: Daehannarae publishing;2003.p.15,
4. Kim EJ, Kwon YI, Lim SH. Bracketless full arch fixed orthodontic treatment with esthetic simple-tubes in an adult. Clin J Korean Assoc Orthod. 2020;10:264-273.
5. Jeong SR, Kim HI, Lim SH. Treatment of class I crowding using simple tubes bonded with customized resin coverings: A case report. Korean J Orthod. 2019;49:116-123.
6. Hwang HS, Jeon HR, Kim SP, Kim WS, Lee GH. A new orthodontic appliance for rapid anterior alignment in adults; minitube appliance (MTA). J Korean Dent Assoc. 2011;49:398-409.
7. Kim SY, Lee SH, Lee NY, Jih MK. Forced eruption with customized resin tube appliance. Oral Biol Res. 2018;42:45-52.
8. Johnson JE. The twin-wire appliance. Am J Orthod. 1938;24:303-327.
9. Johnson JE. The construction and manipulation on the twinwire mechanism. Am J Orthod Oral Surg. 1941;27:202-215.
10. Park SH, Lee YK, Chun YS. Correction of palatally displaced maxillary lateral incisors using a tube system. J Clin Orthod. 2008;42:461-465.
11. Turkkahraman H, Sayin MO, Bozkurt FY, Yetkin Z, Kaya S, Onal S. Archwire ligation techniques, microbial colonization, and periodontal status in orthodontically treated patients. Angle Orthod. 2005;75:231-236.
12. Nam JS, Park SK. Easy entire orthodontic treatment with Itube. Seoul: Myungmun publishing; 2016.p.13-16,37-38.
13. Hwang HS, Jeon HR, Lee KM, Boyd R. Use of a minitube appliance in periodontally compromised adult patients with severely displaced incisors. J Clin orthod. 2016;50:533-542.
14. Proffit WR, Fields HW, Sarver DM. Contemporary orthodontics. Seoul: Daehannarae publishing; p.292-294.
15. Park YC. Contemporary lingual orthodontics. Seoul: Daehannarae publishing; 2015.p.300-305.
16. Hwang HS. Orthodontic management of horizontal and vertical space problems in prosthodontics. J Korean Acad Prosthodont. 2000;38:412-420.