ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Validation and Applications of Gas Chromatography-Combustion/isotope Ratio Mass Spectrometric Method to Control Misuse of Androgens in Human

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2011, v.2 no.2, pp.33-36
https://doi.org/10.5478/MSL.2011.2.2.033
Kang Mi Lee (Korea Institute of Science and Technology)
Ho Jun Kim (Korea Institute of Science and Technology)
Eun Sook Jeong (Korea Institute of Science and Technology)
Hye Hyun Yoo (Hanyang University)
Oh-Seung Kwon (Korea Institute of Science and Technology)
Changbae Jin (Korea Institute of Science & Technology)
Dong Hyun Kim (Inje University)
Jaeick Lee (Korea Institute of Science and Technology)
  • 다운로드 수
  • 조회수

Abstract

The misuse of anabolic androgenic steroids is of particular concern in sports and society. Thus, it is of great importance todiscriminate endogenous steroids such as testosterone or testosterone prohormones from their chemically identical syntheticcopies. In this study, gas chromatography-combustion/isotope ratio mass spectrometric (GC−C/IRMS) method has been developedand validated for discriminating the origin of anabolic androgenic steroids. The method involves the solid-phase extraction,enzymatic hydrolysis with β-glucuronidase, HPLC-fractionation for the cleanup and analysis by GC−C/IRMS. The difference(Δ13C) of urinary δ13C values between synthetic analogues and endogenous reference compounds (ERC) by GC−C/IRMS wasused to elucidate the origin of steroids, and intra- and inter-day precision, specificity and isotope fractionation were evaluated. The present GC−C/IRMS method combined with HPLC cleanup was accurate and reproducible enough to be successfullyapplied to the test of urine sample from suspected anabolic steroid abusers.

keywords
Steroids, Endogenous, Validation, GC-C/IRMS


참고문헌

1

Cawley, A. T. (2009). . V. Steoids, 74, 379-.

2

The World Anti-Doping Agency. Prohibited List.

3

Chung, B. C. (1990). . J. Anal. Toxicol, 14, 91-.

4

Coppen, J. J. W.. (1979). . Trop. Sci, 21, 125-.

5

Ueki, M. (1999). . Rapid Commun. Mass Spectrom, 13, 2237-.

6

Becchi, M. (1994). . Rapid Commun. Mass Spectrom, 8, 304-.

7

Aguilera, R. (1996). . J. Mass Spectrom, 31, 169-.

8

Shackleton, C. H. L.. (1997). . Steoids, 62, 379-.

9

Cawley, A. T. (2008). . J. Mass Spectrom, 43, 854-.

10

Mareck, U. (2008). . J. Mass Spectrom, 43, 877-.

11

Shackleton, C. H. L. (1997). . Steoids, 62, 665-.

12

Aguilera, R. (1999). . J. Chromatogr. B, 727, 95-.

13

Aguilera, R. (2001). . Clin.Chem, 47, 292-.

14

Piper, T. (2008). . Rapid Commun. Mass Spectrom, 22, 2161-.

15

Saudan, C. (2009). . J.Chromatogr. B, 877, 2321-.

투고일Submission Date
2011-03-03
수정일Revised Date
2011-03-24
게재확정일Accepted Date
2011-06-08
상단으로 이동

Mass Spectrometry Letters