ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Determination of Mercury in Fly Ash by Using Flow Injection Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2012, v.3 no.2, pp.58-61
https://doi.org/10.5478/MSL.2012.3.2.58
Jung Ki Suh (Korea Research Institute of Standards and Science)
Hyung Sik Min (Korea Research Institute of Standards and Science)
Mohammad Kamruzzaman (Kyungpook National University)
Sang Hak Lee (Kyungpook National University)
  • 다운로드 수
  • 조회수

Abstract

A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. 200Hg isotopic spike was added to 0.25 g of BCR176Rfly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL HNO3 + 2 mLHCl + 2 mL HF) and acid mixture B (8 mL HNO3 + 2 mL HClO4 + 2 mL HF) for applying IDMS. Mercury cold vapor was generatedby using reductant solution of 0.2% (w/w) NaBH4 and 0.05% (w/w) NaOH. The measurements of n(200Hg)/n(202Hg) isotoperatio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified referencematerial (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was 1.60 ± 0.23 mg/kg (k = 2). The determinedvalues of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were 1.60 ± 0.24 mg/kg(k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.

keywords
Mercury, Flow injection, Cold-vapor, Isotope dilution-inductively coupled plasma mass spectrometry, BCR CRM 176R, Fly ash


참고문헌

1

Mann, J. L. (2003). . J. Anal. At. Spectrom, 18, 1293-.

2

Costley, C. T. (2000). . Anal. Chim. Acta, 405, 179-.

3

Armstrong, H. L. (1999). . Anal. Chim. Acta, 390, 245-.

4

Allibone, J. (1999). . J. Anal. Atom. Spectrom, 14, 235-.

5

Milton, M. J. T. (2001). . Metrologia, 38, 289-.

6

Jian, L. (2000). . Fresenius’ J. Anal. Chem, 366, 48-.

7

Karunasagar, D. (1998). . J. Anal. Atom. Spectrom, 13, 679-.

8

Chen, S. F. (1998). . J. Anal. Atom. Spectrom, 13, 673-.

9

Liao, H. C. (1999). . J. Anal. Atom. Spectrom, 14, 1583-.

10

Long, S. E. (2002). . Anal. Chem, 74, 1477-.

11

Willie, S.. (2002). . Am. Lab, 34, 40-.

12

Mester, M. (1999). . Analytica Chimica Acta, 395, 157-.

13

Woller, Á. (1997). . J. Anal. Atom. Spectrom, 12, 53-.

14

De Bièvre, P.. (1994). . J. Fresenius Anal. Chem, 350, 277-.

15

Guide to the expression of uncertainty in measurement: SBN 92-67-10188-9.

16

Tayor, B. N. (1994). Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results. U. S. Government Printing Office.

17

EURACHEM Guide: The fitness for purpose of analytical methods. A laboratory guide to method validation and related topics.

18

Taylor H. E. (2001). Inductively coupled plasma mass spectrometry: Practice and techniques:Academic Press.

투고일Submission Date
2012-02-17
수정일Revised Date
2012-06-18
게재확정일Accepted Date
2012-06-18
상단으로 이동

Mass Spectrometry Letters