• P-ISSN2233-4203
  • E-ISSN2093-8950
  • ESCI, SCOPUS, KCI

Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Determination of Mercury in Fly Ash by Using Flow Injection Cold Vapor Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2012, v.3 no.2, pp.58-61
https://doi.org/10.5478/MSL.2012.3.2.58
Suh Jung Ki (Korea Research Institute of Standards and Science)
Min Hyung Sik (Korea Research Institute of Standards and Science)
Kamruzzaman Mohammad (Kyungpook National University)
Lee Sang Hak (Kyungpook National University)
  • Downloaded
  • Viewed

Abstract

A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. 200Hg isotopic spike was added to 0.25 g of BCR176Rfly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL HNO3 + 2 mLHCl + 2 mL HF) and acid mixture B (8 mL HNO3 + 2 mL HClO4 + 2 mL HF) for applying IDMS. Mercury cold vapor was generatedby using reductant solution of 0.2% (w/w) NaBH4 and 0.05% (w/w) NaOH. The measurements of n(200Hg)/n(202Hg) isotoperatio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified referencematerial (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was 1.60 ± 0.23 mg/kg (k = 2). The determinedvalues of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were 1.60 ± 0.24 mg/kg(k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.

keywords
Mercury, Flow injection, Cold-vapor, Isotope dilution-inductively coupled plasma mass spectrometry, BCR CRM 176R, Fly ash


Reference

1

Mann, J. L. (2003). . J. Anal. At. Spectrom, 18, 1293-.

2

Costley, C. T. (2000). . Anal. Chim. Acta, 405, 179-.

3

Armstrong, H. L. (1999). . Anal. Chim. Acta, 390, 245-.

4

Allibone, J. (1999). . J. Anal. Atom. Spectrom, 14, 235-.

5

Milton, M. J. T. (2001). . Metrologia, 38, 289-.

6

Jian, L. (2000). . Fresenius’ J. Anal. Chem, 366, 48-.

7

Karunasagar, D. (1998). . J. Anal. Atom. Spectrom, 13, 679-.

8

Chen, S. F. (1998). . J. Anal. Atom. Spectrom, 13, 673-.

9

Liao, H. C. (1999). . J. Anal. Atom. Spectrom, 14, 1583-.

10

Long, S. E. (2002). . Anal. Chem, 74, 1477-.

11

Willie, S.. (2002). . Am. Lab, 34, 40-.

12

Mester, M. (1999). . Analytica Chimica Acta, 395, 157-.

13

Woller, Á. (1997). . J. Anal. Atom. Spectrom, 12, 53-.

14

De Bièvre, P.. (1994). . J. Fresenius Anal. Chem, 350, 277-.

15

Guide to the expression of uncertainty in measurement: SBN 92-67-10188-9.

16

Tayor, B. N. (1994). Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results. U. S. Government Printing Office.

17

EURACHEM Guide: The fitness for purpose of analytical methods. A laboratory guide to method validation and related topics.

18

Taylor H. E. (2001). Inductively coupled plasma mass spectrometry: Practice and techniques:Academic Press.

Submission Date
2012-02-17
Revised Date
2012-06-18
Accepted Date
2012-06-18
상단으로 이동

Mass Spectrometry Letters