ACOMS+ 및 학술지 리포지터리 설명회

  • 한국과학기술정보연구원(KISTI) 서울분원 대회의실(별관 3층)
  • 2024년 07월 03일(수) 13:30
 

  • P-ISSN1225-0163
  • E-ISSN2288-8985
  • SCOPUS, ESCI, KCI

논문 상세

Home > 논문 상세
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

논문 상세

    Simultaneous determination of illegal galactagogue adulterants in supplement diets by LC-MS/MS

    분석과학 / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
    2018, v.31 no.4, pp.171-178
    https://doi.org/10.5806/AST.2018.31.4.171
    이지현 (식품의약품안전처)
    조소현 (식품의약품안전처)
    박한나 (식품의약품안전처)
    박형준 (식품의약품안전처)
    김남숙 (식품의약품안전처)
    박성관 (식품의약품안전처)
    강호일 (식품의약품안전처)
    • 다운로드 수
    • 조회수

    Abstract

    Recently, for successful lactation, many breastfeeding mothers seek various products, including herbal medicine, dietary supplements, and prescribed medicines, to improve milk production. As demand for galactogogues grows, it is highly possible that pharmaceutical galactogogues may be adulterated with illegal products to maximize their efficacy. For continuous control and supervision of illegal products, we developed and validated a simple and sensitive LC-MS/MS method capable of simultaneously determining five galactogogues. Chromatographic separation was conducted using an Agilent Poroshell 120 SB-C18 column with a mobile phase consisting of 20 mM ammonium formate (pH 5.4) and 100 % acetonitrile. The total run time was 13 min per analyte. The proposed method was performed according to the guidelines of the International Conference of Harmonization and it produced reliable results. This method showed high sensitivity and specificity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 0.01-0.82 ng/mL and 0.02-2.45 ng/mL, respectively, for the solid- and liquid-type samples. Specificity was evaluated by analyzing matrix-blank samples spiked with the target compounds at LOQ levels, which provided a good separation of all peaks without interference. Additionally, the repeatability and intermediate precision were typically <15 %, whereas the recovery was 80-120 % of the values obtained using blank samples. Thus, we concluded that this method could be used for the identification and quantification of galactogogues in food or herbal products.

    keywords
    galactogogues, breastfeeding, lactation, LC-MS/MS, validation, dietary supplement


    참고문헌

    1

    M. Wilinska, and E. Schleubner, Nutrafoods, 14, 119-125 (2015).

    2

    F. Penagos Tabares, J. V. Bedoya Jaramillo, and Z. T. Ruiz-Cortez, Vet. Med. Int., 2014, 1-20 (2014).

    3

    A. A. Zuppa, P. Sindico, C. Orchi, C. Carducci, V. Cardiello, and C. Ramagnoli, J. Pharm. Pharm. Sci., 13, 162-174 (2010).

    4

    A. B. Forinash, A. M. Yancey, K. L. Barnes, and T. D. Myles, Ann. Pharmacother., 46, 1392-1404 (2012).

    5

    E.W. Wan, K. Davey, M. Page-Sharp, P. E. Hartmann, K. Simmer, and K. F. Ilett, Br. J. Clin Pharmacol., 66, 283-289 (2008).

    6

    F. J. Nice, Child Obes. Nutr., 3, 129-132 (2011).

    7

    C. M. Betzold, and J. Midwifery Women's Health, 49, 151-154 (2004).

    8

    A. Osadchy, M. E. Moretti, and G. Koren, Obstet. Gynecol. Int., 2012, 1-7 (2012).

    9

    M. Mortel and S. D. Mehta, J. Hum. Lact., 29, 154-162 (2013).

    10

    I. Gbadamosi and O. Okolosi, J. Appl. Biosci., 61, 4460-4469 (2013).

    11

    M. P. Gabay, J. Hum. Lact., 18, 274-279 (2002).

    12

    H. C. Sachs, Pediatr., 132, 796-809 (2013).

    13

    J. H. Lee, N. S. Kim, K. M. Han, S. H. Kim, S. Cho, and W. S. Kim, Food Addit. Contam. Part A, 30, 1849-1857 (2013).

    14

    H. J. Kim, J. H. Lee, H. J. Park, S. H. Cho, S. Cho, and W. S. Kim, Food Addit. Contam. Part A, 31, 777-783 (2014).

    15

    S. H. Cho, H. J. Park, J. H. Lee, H. J. Kim, S. Cho, C. Y. Yoon, and W. S. Kim, Food Addit. Contam. Part A, 31, 1470-1475 (2014).

    16

    M. Kobylinska, K. Kobylinska, J. Chromatogr. B., 744, 207-212 (2000).

    17

    L. Curtin Whelan, M. Geary, M. Wharton, and P. Sweetman, J. Chromatogr. Sci., 53, 226-232 (2015).

    18

    H. Lamparczyk, A. Chmielewska, L. Konieczna, A. Plenis, and P. K. Zarzycki, J. Biomed. Chromatogr., 15, 513-517 (2001).

    19

    L.Vlase, A. Leucuta, D. Farcau, and M. Nanulescu, J. Biopharm. Drug Dispos., 27, 285-289 (2006).

    20

    V. Michaud, C. Simard, and J. Turgeon, J. Chromatogr. B, 852, 611-616 (2007).

    21

    K. W. Riggs, A. Szeitz, D. W. Rurak, A. E. Mutlib, F. S. Abbott, and J. E. Axelson, J. Chromatogr. B, 660, 315-325 (1994).

    22

    E. Saar, D. Gerostamoulos, and O. H. Drummer, J. Beyer, Anal. Bioanal. Chem., 393, 727-734 (2009).

    23

    E. Saar, D. Gerostamoulos, O. H. Drummer, and J. Beyer, J. Mass Spectrom., 45, 915-925 (2010).

    24

    M. Yan, H. D. Li, B. M. Chen, X. L. Liu, and Y. G. Zhu, J. Chromatogr. B., 878, 883-887 (2010).

    25

    A. Bose, U. Bhaumik, A. Ghosh, B. Chatterjee, U. S. Chakrabarty, A. K. Sarkar, and T. K. Pal, Chromatogr., 69, 1233-1241 (2009).

    26

    M. J. Smit, F. C. W. Sutherland, H. K. L. Hundt, K. J. Swart, A. F. Hundt, and J. Els, J. Chromatogr. A, 949, 65-70 (2002).

    27

    T. Kubo, K. Kuroda, Y. Tominaga, T. Naito, K. Sueyoshi, K. Hosoya, and K. Otsuka, J. Pharm. Biomed. Anal., 89, 111-117 (2014).

    상단으로 이동

    분석과학