Article Detail

Home > Article Detail
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

Article Contents

    Establishment for analytical method of methanol in wet wipes by headspace gas chromatography

    Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
    2016, v.29 no.5, pp.242-247
    https://doi.org/10.5806/AST.2016.29.5.242









    • Downloaded
    • Viewed

    Abstract

    This research aims to set up and validate methods of analyzing the methanol in wet wipes and verifies the analysis methods that applied to the wet wipes. We used Headspace (HS) Gas Chromatography (GC) - Flame Ionization Detector (FID) to the establish analysis method of methanol in wet wipes and optimized heating temperature, heating time, GC conditions with column. The result indicated that 3 mL of sample in 20 mL headspace vial can be equilibrated efficiently in headspace sampler at 70 oC for 10 min and sample was measured by GC with spli injection mode(10:1). The results show that linearity from 1 to 100 ppm was over R2 0.9995, precision was RSD 1.83 % and accuracy(recovery rate) was 105.44 (±1.05 %) on water matrix and wet wipes matrix removed non-woven fabric. Also, monitoring results of total 20 cosmetics on the market, from 0.00017 to 0.00156 % of methanol was detected from wet wipes.

    keywords
    cosmetic, methanol, wet wipes, headspace gas chromatography


    Reference

    1

    1. D. Jacobsen and K. E. McMartin, Methanol and ethylene glycol poisonings. Mechanism of toxixity, clinical course, diagnosis and treatment. Med. Tocicol., 1, 309-334 (1986).

    2

    2. R. j. Meyer, M. E. Beard and M. W. Ardagh, Henderson S. Methanol poisoning. N. Z. Med. J., 113, 11-13(2000).

    3

    3. P. A. Stafford and C. S. Ough, Formation of methanol and ethyl methyl carbonate by dimethyl dicarbonate in wine and model solutions. Am. J. Enol Vitic., 27, 7-11(1976).

    4

    4. C. E. Becker, Methanol poisoning. J. Emerg. Med., 1, 51-58 (1983).

    5

    5. A. Turla, N. Yayci and S. Koc, Olumle sonuclanan metil alkol Zehirlenmeleri. Adli Typ Derg., 15, 37-44(2001).

    6

    6. Regulations on the Safety Standard, etc. of Cosmetics (Ministry of Food and Drug Safety, 2013-24, 2013).

    7

    7. Standards and Test Methods of Functional Cosmetics (Ministry of Food and Drug Safety, 2013-28, 2013).

    8

    8. Guideline for analysis method of restricted (prohibited)ingredients of cosmetics (Ministry of Food and Drug Safety, B2-2013-4-002, 2013).

    9

    9. Guideline for the validation of drug analysis procedure (Ministry of Food and Drug Safety, B1-2012-2-013, 2012).

    10

    10. Self-Regulatory Safety Confirmation (industrial product)Annex 49 Wet wipes (Ministry of Food and Drug Safety).

    11

    11. ISO 11423-1 Water qualiry-Determination of benzene and some derivatives (Part1: Head-space gas chromatographic method).

    상단으로 이동

    Analytical Science and Technology