Article Detail

Home > Article Detail
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

Article Contents

    Identifying the potential target substance of physical developer (PD) for reagent reliability test and a study on storage period of TWEEN® 20 based PD working solution

    Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
    2023, v.36 no.3, pp.113-120
    https://doi.org/10.5806/AST.2023.36.3.113
    Ahn Soo-Jeong (Soonchunhyang University)
    Lee Ye-Jin (Soonchunhyang University)
    Yu Je-Seol (Soonchunhyang University)
    • Downloaded
    • Viewed

    Abstract

    Physical developer (PD) is an effective technique that can develop fingerprints even on wet or very old paper. However, it has not been known which substance reacts with PD. Also, the timing of optimization according to the storage period of the PD working solution has not been known. The present research has done a spot test with 7 eccrine components and 5 sebaceous components that known as fingerprint components and figured out the mixture of palmitic acid and lysine gave the strongest positive reaction. Also, paper treated with PD was treated in 1,2-indanedione/zinc (1,2-IND/Zn) working solution and showed lysine was not dissolved in water. To find out the timing of optimization according to the storage period of the TWEEN® 20 based PD working solution, the mixture of palmitic acid and lysine was used for the target of reagent reliability test. As the result, working solution of 14 days storage period showed better result than other working solutions.

    keywords
    fingerprint, physical developer, reagent reliability test, storage period


    상단으로 이동