To determine the contents of <TEX>$^{99}Tc$</TEX> in the spent PWR (pressurized water reactor) nuclear fuels by ICP-MS (inductively coupled plasma-mass spectrometry), a technetium separation method using an extraction chromatographic resin (TEVA Spec resin) has been established. <TEX>$^{99}Tc$</TEX> was separated from a spent PWR nuclear fuel solution by this separation procedure and its concentration was determined by ICP-MS. The result agrees well with the value calculated by the program ORIGEN 2 and also the value measured by AG MP-1 resin/ICP-MS method described in our previous paper. It can be concluded that the present separation procedure is superior to the AG MP-1 resin procedure with respect to the time required for technetium separation as well as the efficiency of decontamination from other radioactive nuclides.
(1960.) The Radiochemistry of Technetium,