Abstract

In this study, soxhlet extraction and dissolution-precipitation method are used for separating analyte from polymer materials. In soxhlet extraction efficiency test, it has been found that the DCM, Toluene, THF, and mixtures Acetone/Hexane (1:4, v/v) gave good extraction efficiency, while the use of the ethyl ether, acetone/ethyl ether (1:4, v/v), acetone/hexane (1:1, v/v), DCM/hexane (1:1, v/v) resulted in significantly lower values. In case of dissolution-precipitation method, there is no considerable difference with used different dissolving solvent. The elution amount of multi layer silica and Florisil column were determined with hexane 250 mL and 70 mL of hexane, respectively. Range of PBDE in real waste plastics was N.D.~1,028 ppm.

keywords
PBDEs, Soxhlet, Dissolution-precipitation, waste, polymer material