바로가기메뉴

본문 바로가기 주메뉴 바로가기

logo

  • KOREAN
  • P-ISSN2287-8327
  • E-ISSN2288-1220
  • SCOPUS, KCI

Vulnerability of Pinus densiflora to forest fire based on ignition characteristics

Journal of Ecology and Environment / Journal of Ecology and Environment, (P)2287-8327; (E)2288-1220
2010, v.33 no.4, pp.343-349


Abstract

In Korea, man-caused forest fires are known originate primarily in coniferous forests. We have hypothesized that the vulnerability of Pinus densiflora forests is principally a consequence of the ignition characteristics of the species. To assess this hypothesis, we conducted two combustion experiments using fallen leaves with a reference species, Quercus variabilis. In the first experiments, in which a cigarette was employed as a primary heat source for the initiation of a forest fire, the Pinus leaves caught fire significantly faster (1´1˝ at Pinus, 1´31˝ at Quercus, P < 0.001), and ignition proceeded normally. Quercus leaves, on the other hand, caught fire but did not ignite successfully. In the second set of experiments utilizing different moisture contents and fuel loads, the maximum flame temperature of the Pinus leaves was significantly higher (421°C at Pinus, 361°C at Quercus, P < 0.001) and the combustion persisted for longer than in the Quercus leaves (8´8˝ at Pinus, 3´38˝ at Quercus, P < 0.001). The moisture contents of the leaves appeared to be a more important factor in the maximum temperature achieved, whereas the most important factor in burning time was the amount of fuel. Overall, these results support the assumption that Pinus leaves can be ignited even by low-heat sources such as cigarettes. Additionally, once ignited, Pinus leaves burn at a relatively high flame temperature and burn for a prolonged period, thus raising the possibility of frequent fire occurrences and spread into crown fires in forests of P. densiflora.

keywords
burning time, cigarette, forest fire, ignition characteristics, maximum flame temperature, Pinus densiflora, Quercus variabilis, vulnerability

Reference

1.

Aerts R. 1997. Climate, leaf litter chemistry and leaf litter decomposition in terrestrial ecosystems: a triangular relationship. Oikos 79: 439-449.

2.

Burgan RE, Rothermel RC. 1984. BEHAVE: Fire Behavior Prediction and Fuel Modeling System-Fuel Subsystem. General Technical Report INT-167. U.S. Department of Agriculture, Forest Service, Intermountain Forest and Range Experiment Station, Ogden, UT.

3.

Chandler C, Cheney P, Thomas P, Trabaud L, Williams D. 1983. Fire in Forestry: Vol. 1. Forest Fire Behavior and Effects. John Wiley & Sons, New York, NY.

4.

Choung Y, Lee BC, Cho JH, Lee KS, Jang IS, Kim SH, Hong SK, Jung HC, Choung HL. 2004. Forest responses to the large-scale east coast fires in Korea. Ecol Res 19: 43-54.

5.

Graham JB, McCarthy BC. 2006. Effects of fine fuel moisture and loading on small scale fire behavior in mixed-oak forests of southeastern Ohio. Fire Ecol 2: 100-114.

6.

Haessler WM. 1989. Fire: Fundamentals and Control. Marcel Dekker, Inc., New York, NY.

7.

Hely C, Bergeron Y, Flannigan MD. 2000. Effects of stand composition on fire hazard in mixed-wood Canadian boreal forest. J Veg Sci 11: 813-824.

8.

Kim KS, Jang IS, Kim SJ. 1994. Moisture content of litter layer and its combustibility by cigarette light in forest. Korean J Ecol 17: 1-9. (in Korean)

9.

Korea Forest Service. 2009. National forest statistics. http://www.forest.go.kr/foahome/user.tdf?a=user.localstat.LocalStatApp&c=1001&mc=WWW_INFORMATION_STAT_010&aYear=2008&agubun1=1&asido=2&argubun=1. Accessed 26 November 2009.

10.

Lee HP, Lee SY, Park YJ. 2009. A study on thermal characteristics and ignitability of dead leaves and living leaves for main species of trees in Youngdong areas. J Korean Inst Fire Sci Eng 23: 21-32. (in Korean)

11.

Lee SY, Won MS, Han SY. 2005. Developing of forest fire occurrence danger index using fuel and topographical characteristics on the condition of ignition point in Korea. Trans Korean Inst Fire Sci Eng 19: 75-79. (in Korean)

12.

Park HJ, Kim, ES, Kim JH, Kim DH. 2007. A combustion characteristic analysis of Quercus variabilis and Pinus densiflora fallen leaves using radiation heat flux. J Korean Inst Fire Sci Eng 21: 41-46. (in Korean)

13.

Seo H. 2010. Comparison of fire vulnerability at Pinus densiflora and Quercus variabilis forests in East Coast of Korea. MS Thesis. Kangwon National University, Chuncheon, Korea.

14.

Song HK, Kim JK. 1994. Essential oil components of leaves and resins from Pinus densiflora and Pinus koraiensis. Mokchae Konghak 22: 59-67. (in Korean)

Journal of Ecology and Environment