- P-ISSN 1225-0163
- E-ISSN 2288-8985
The iodide was recovered from a simulated spent fuel to the sodium bisulfite aqueous solution. It was discussed that the trace iodide (below 1 ppm) was determined without the matrix effect of 0.1 M sodium bisulfite and 1 mM <TEX>$HNO_3$</TEX> in aqueous solution by ion chromatography with UV detection. AS4A-SC (DIONEX) column and UV-absorption spectrophotometer were used. The UV-absorption spectra of sodium bisulfite, nitric acid and iodide were obtained, and then 230 nm was selected as an absorption wavelength for iodide determination. 0.1 M NaCl eluent was optimum condition. In this condition the calibration curve of iodide was obtained on the range of about 0-1,000 ppb. The linear coefficient was 0.99993 and the detection limit was 5 ppb. The relative standard deviation was 1.26%.