- P-ISSN 1225-0163
- E-ISSN 2288-8985
For the evaluation of our laboratory's 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH)urinalysis test, THCCOOH urinalysis test was carried out with Certified Reference Material (CRM). The used CRM was THCCOOH in freeze-dried urine produced by NIST as Standard Reference Material 1507b. Comparing the estimated value of our laboratory with CRM, the results was coincided in the confidence level of approximately 95%.
1. ‘2008 Drug control in Korea’, Supreme Prosecutors' Office.
2. V. Rajananda, V. Navarantnam and N. K. Nair, ‘Analytical methods for the identification of the principal cannabinoids metabolite in urine’, 113 V. Navarantnma Ed., National Drug Research Centre Universiti Sains, Malaysia, 1985.
3. ‘TDx/TDxFLx; Cannabinoids’, 10, Abbott Laboratories, U.S.A, 1994.
4. R. A. Gustafson, E. T. Moolchan, A. Barnes, B. Levine and M. A. Huestis, J. Chromatogr. B, 798, 145-154(2003).
5. P. Kintz, D. Machart, C. Jamey and P. Mangin, J. Anal. Toxicol., 19(5), 304-306(2000).
6. P. Kintz and V. Cirmele, Biomed. Chromatogr., 11, 371-376(1997).
7. C. Staub, J. Chromatogr. B, 733, 199-126(1999).
8. M. A. Huestis, J. M. Mitchell and E. J. Cone, J . Anal. Toxicol., 20(6), 441-452(1996).
9. M. A. Elsohly and S. Feng,, J. Anal. Toxicol., 20(4), 329-335(1998).
10. D. A. Armbruster, R. H. Schwarzhoff, E. C. Hubster and M. K. Liserio, Clin. Chem., 39, 2137-2141(1993).
11. P. M. Kemp, I. K. Abukhalaf, J. E. Manno, B. R. Manno, D. D. Alford, M. E. Mcwilliams, F. E. Nixon, M. J. Fitzgerald, R. R. Reeves and M. J. Wood, J. Anal. Toxicol., 19(5), 292-298(1995).
12.. H. Teixeira, P. Proenca, A. Castanheira, S. Santos, M. Lopez-Rivadulla, F. Corte-Real, E. P. Marques and D. N. Vieira, Forensic Sci. Int., 146, Suppl: S61-63(2004).
13. G. M. Aballero, C. D'Angelo, M. S. Fraguio and O. T. Cenrurion, J. Chromatogr. Sci., 42(10), 540-544(2004).
14. H. Teixeira, P. Proenca, A. Verstanete, F. Corte-Real, and D. N. Vieira, Forensic Sci. Int., 150, 205-211(2006).
15. M. A. Elsohly, S. Feng, W. J. Kopycki, T. P. Murply, A. B. Jones, A. Davis and D. Carr, J. Anal. Toxicol., 21(3), 240-242(1997).
16. ISO Guide 35, ‘Ceritification of reference materialgeneral and statistical principles’, ISO, Geneva.
17. A. M. H. vander Veen, Accred. Qual. Assur., 7, 2-6(2002).
18. 측정불확도 표현지침, 한국표준과학연구원 (1998).
19. 측정결과의 불확도 산정 및 표현을 위한 지침, KOLAS(Korea Laboratory Accreditation Scheme) (2000).
20. 숙련도시험운영기준, KOLAS(Korea Laboratory Accreditation Scheme) (2007).
21. 김진영, 정재철, 서승일, 서용준, 이정직, 김종상, 인문교, 약학회지, 52, 480-487(2008).
22. 정재철, 김진영, 인문교, 정원조, 한국분석과학회지, 19(5), 441-448(2006).
23. 최종오, 소헌영, 우진춘, 황의진, 한국분석과학회지, 15(6), 580-583(2002).