Article Detail

Home > Article Detail
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

Analysis of Dioxins in Meat by HRGC/HRMS

Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
2001, v.14 no.1, pp.88-93
Choi, Dongmi
Hu, Soojung
Jeong, Jiyoon
Won, Kyungpoong
  • Downloaded
  • Viewed

Abstract

To measure the levels of dioxins in food selling at local markets, meat was analyzed by high resolution gas chromatography/high resolution ass spectrometry (HRGC/HRMS). The food samples were obtained from 5 large cities of Seoul, Chunchon, Daejon, Kwangju and Busan in Korea. All the samples were minced and extracted with Soxhlet extractor for 18 hours. After extraction, extracts were cleaned up by sulfuric acid impregnated silica gel, purified on a series of silica gel, alumina, carbon column chromatography and then analyzed by HRGC/HRMS. The contaminated levels were calculated as the TEQs by multiplying with the corresponding WHO-TEFs for each congeners. The overall recoveries were ranged from 80% to 153% and the limit of detection was about 0.01 ppt at S/N>3. The levels of PCDD/Fs for beef, pork and chicken were 0.018, 0.008 and <0.001 pgTEQ/g, respectively. In addition, the levels of non-ortho-co-planar PCBs for beef, pork and chicken were 0.008, 0.002 and 0.001 pgTEQ/g, respectively. Among food samples analyzed, chicken showed the lowest level of dioxin-like compounds. Regarding congener pattern, OCDD and PCB #77 were the highest contributing congeners.

keywords
dioxins, PCBs, pork, beef, chicken