Twenty-two allergy-induced aromatics in children were analyzed using a gas chromatography flame ionization detector (GC-FID) and gas chromatography mass spectrometer (GC-MSD). Analytes were extracted using an automatic Soxhlet extractor and centrifuged for 10 min in a fast freezing centrifuge, and the supernatant was transferred into a 2 mL vial and injected in split mode. Under the established conditions, the calibration curve showed linearity with a correlation coefficient of 0.996 or more. A wide range of sensitivity of 6.7 to 1,859,839 depending on the device characteristics and detector used was shown. The detection limit of the device was 0.0032 to 0.0335 μg/mL, and the maximum detection limit was less than 0.1 μg/mL. The detection limit of the method ranged from 0.0033 to 0.1161 μg/mL. In addition, the limit of quantification ranged from 0.0100 to 0.5422 μg/mL, with a level of precision ranging from 0.21 % to 4.89 % and a degree of accuracy ranging from 89 % to 111 %. The analytical method developed in this study was applied to commercial products.

keywords
allergy, aromatic material, children's products, GC-FID, GC-MSD


Reference

1

Korea Ministry of Environment, 'Final Report of the Survey on the third Chemical Substance Distribution', 37, 2007.

2

Directive 2009/48/EC, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 June 2009 on the safety of toys', Off. J. Eur. Union, 2009.

3

Directive 2003/15/EC, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 February 2003', Off. J. Eur. Union, 2003.

4

Regulation (EC) No 1223/2009, 'OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 on cosmetic products', Off. J. Eur. Union, 2009.

5

SCCNFP, 'An Initial List of Perfumery Materials which must not form part of Fragrance Compounds used in Cosmetic Products', 2000.

6

SCCNFP, 'The 1st Update of the Inventory of Ingredients Employed in Cosmetic Products, SECTION II: Perfume and Aromatic Raw Materials', 2000.

7

SCCNFP, 'An Update of the Initial List of Perfumery Materials which must not form part of Fragrance Compounds used in Cosmetic Products', 2003.

8

EN 71-3, 'Migration of certain elements', 2014.

9

Korea Ministry of Government Legislation (http://www.law.go.kr/lsInfoP.do?lsiSeq=180383&efYd=20170128#0000).

10

F. David, C. Devos and P. Sandra, LC.GC Eur., 19(11), 602-616 (2006).

11

Y. Uda and Y. Maeda, Agric. Biol. Chem., 50(1), 205-208 (1986).

12

L. H. Wang and H. J. Liu, J. Bioequiv. Availab., 2(3), 72-76 (2010).

13

B. Desmedt, M. Canfyn, M. Pype, S. Baudewyns, V. Hanot, P. Courselle, J. O. De Beer, V. Rogiers, K. De Paepe, and E. Deconinck, Talanta, 131, 444-451 (2015).

14

H. Leijs, J. Broekhans, L. Van Pelt and C. Mussinan, J. Agric. Food Chem., 53, 5487-5491 (2005).

15

IFRA, 'Analytical Procedure Version 3, GC/MS Quantitation of potential fragrance allergens in fragrance compounds', 2007.