Article Detail

Home > Article Detail
  • P-ISSN 1225-0163
  • E-ISSN 2288-8985

Validation of urinary N-methylacetamide reference material for proficiency test

Analytical Science and Technology / Analytical Science and Technology, (P)1225-0163; (E)2288-8985
2014, v.27 no.6, pp.339-346
https://doi.org/10.5806/AST.2014.27.5.339

  • Downloaded
  • Viewed

Abstract

The author assessed the availability of urine reference material for proficiency test provided forlaboratories in occupational health. N-methylacetamide is the biomarker of exposure to N,N-dimethyl acetamide,which was used as the substitute for hepatotoxic N,N-dimethylformamide (DMF). N-methylacetamide (NMAC)urine samples of 3 different levels covering the 0.2~2 times of the exposure limit were tested. Stability testup to 180 days (0, 7, 30, 60, 180 days) at 4 different temperatures (-60, -20, 5, 25 oC) and homogeneity testwere performed for these samples. New analytical condition by GC/MSD using SIM mode (m/z 58, 59) andDB-624 column was investigated for better selectivity, sensitivity and resolution. Urinary NMAC samplesshowed good homogeneity for 3 levels. These samples also showed good stability up to 180 days. The dataof stability and homogeneity of urinary DMAC confirmed the basis of including this item into Korean proficiencytest for occupational health laboratories since 2008.

keywords
reference material, urinary N-methylacetamide, proficiency test, biological monitoring


Reference

1

1. ISO Reference materials - General and statistical principles for certification: ISO Guide 35: 2006 : International Organization for Standardization (2006).

2

2. Korea research institute of standards and science http://crm.kriss.re.kr/(2007).

3

3. ISO General requirements for the competence of testing and calibration laboratories: ISO/IEC 17025: Inter-national Organization for Standardization. (1999).

4

4. H. Lim, J. Ryu, S. Choi, A. Choi, H. Jung, J. Ryu, H. Kim and S. Jang, Anal. Sci. Technol., 22(5), 369-375(2009).

5

5. C.-H. Jung, D.-W. Park, S.-M. Kim and E.-C. Yu, Anal. Sci. Technol., 22(1), 82-91 (2009).

6

6. EA The selection and use of reference materials: EA-4/14 (rev.00): European co-operation for Accreditation. (2003).

7

7. J.-S. Yang, Proficiency test program for biological samples for biological monitoring, Korea safety and health agency (1995).

8

8. Practical guide for health examination of workers. Korea safety and health agency. Ministry of labour (2013).

9

9. J.-S. Yang, D. H. Sohn, M.-Y. Lee, S.-K. Kang, Preparation method of reference material for analysis of metabolite of organic solvents in urine. Patent No. 165621, Korean Intellectual Property Office (1998).

10

10. R. Lawn, P. Roper, G. Holcombe, B. Stuart, Low-cost QC laboratory reference materials - Investigation of cost-effective production procedures: LGC/VAM/2001/009: LGC (2001).

11

11. R. Lawn, P. Roper, G. Holcombe and B. Stuart, Application notes for the production of low-cost quality control matrix reference materials: LGC/VAM/2001/010:VAM (2001).

상단으로 이동